90548013 VEC051D INVERTER.qxp 3/6/09 10:31 AM Page 11

Fault Protection and Troubleshooting Guide

INVERTER POWER SWITCH TURNED ON

Trouble/Indication

Possible Cause

Suggested Remedy

No AC output —

DC input is below 10 volts

Recharge or replace battery.

red LED lit

 

 

 

Excessive appliance load

Turn unit OFF. Reduce the load, wait for the

 

— thermal shutdown

inverter to cool down, then turn the unit ON

 

 

again.

No AC output —

Fuse(s) open

Check DC input — fuse(s) in vehicle. Replace

green LED not lit

 

the fuse with one of the same type and

 

 

rating if necessary.

Low battery alarm

Low battery voltage

Recharge battery. Remove load from the

sounds continuously

 

inverter while recharging battery.

 

Bad connection or wiring

Tighten all DC connections.

Motorized power tool

Excessive start-up load

If appliance does not start, appliance is

will not start

 

drawing excessive current and will not work

 

 

with inverter.

Motorized power tool

Purely inductive load

Make the load not purely inductive. Operate

does not operate at

 

an incandescent lamp at the same time as

correct speed

 

motor.

Television/radio

Snow in picture,

Keep inverter and antenna distant from each

interference

“buzzing” sound

other. Use shielded antenna. Connect antenna

 

 

to amplifier.

 

 

 

Resetting the Unit

When a thermal shutdown problem occurs, the inverter will reset and turn back on automatically after it cools.

WARNING: To reduce the risk of injury or property damage: If the appliance stops working, even momentarily, turn off the appliance and disconnect from the inverter until the cause is identified and corrected.

CARE AND MAINTENANCE

Storage

1.Ideal storage temperature range is 50-68°F (10-20°C).

2.Store and use the inverter in a cool, dry place with adequate ventilation.

3.Avoid locations that are exposed to heating units, radiators, direct sunlight or excessive humidity or dampness.

Fuse Replacement

This inverter is equipped with multiple internal fuses. Normally, these fuses will not “blow” unless there is a serious problem inside the unit. Internal fuses are replaceable; however, only trained personnel should attempt fuse replacement. Refer to the “Service Information” section of this Instruction Manual.

Preventive Maintenance

Inverters require minimal maintenance. For optimum performance, the manufacturer recommends periodically performing the following preventive maintenance.

1.Turn OFF the inverter using the front panel ON/OFF Power Switch.

2.Remove the DC power fuse.

3.Check and tighten all electrical connections, including the ground.

4.Using a non-metallic vacuum cleaner hose, vacuum the air slots and fan area.

5.Clean the outside of the unit using a damp (not wet) cloth.

6.Wipe unit surfaces thoroughly with a dry cloth.

7.Re-insert the fuse and resume operation.

11

Page 12
Image 12
Vector VEC051D owner manual Fault Protection and Troubleshooting Guide, Resetting the Unit, Care and Maintenance, Storage