Vermont Castings Defiant

Defiant Clearance Chart

for use with either a 6” or 8” flue collar/chimney connection

 

 

 

 

 

Stove Clearance

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Unprotected Surfaces

Protected Surfaces

 

 

 

 

 

 

 

 

 

 

 

 

Stove Installed

Stove

Stove Installed

Stove

 

 

in

in

 

 

Parallel to Wall

Parallel to Wall

 

 

Corner

Corner

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Side

Rear

Corners

Side

 

Rear

Corners

 

 

 

 

 

 

 

 

 

 

No stove

(A)

24”

(B) 33”

(C) 23”

(D) 14”

 

(E) 28”

(F) 18”

heat shields

(610 mm)

(840 mm)

(585 mm)

(355 mm)

 

(710 mm)

(460 mm)

Stove with rear heat

(G)

24”

(H) 21”

(I) 17”

(J) 14”

 

(K) 17”

(L) 12”

shield, no connector

 

( 610 mm)

(533 mm)

(430 mm)

(355 mm)

 

(430 mm)

(305 mm)

heat shields

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Stove with rear heat

(M)

24”

(N) 17”

(O) 17”

(P) 14”

 

(Q) 17”

(R) 12”

shield, and heat shields

 

(610 mm)

(430 mm)

(430 mm)

(355 mm)

 

(430 mm)

(305 mm)

on connector

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Stove with rear heat

(S) 24”

(T) 17”

(U) 17”

(V) 14”

 

(W) 15”

(X) 12”

shield, and double-wall

 

(610 mm)

(430 mm)

(430 mm)

(355 mm)

 

(380 mm)

(305 mm)

chimney connector*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Chimney Connector Clearance

 

 

 

 

 

 

 

 

 

 

 

Unprotected Vertical Surfaces

Protected Vertical Surfaces

 

 

 

 

 

 

 

 

Single-wall connector

 

 

30” (760 mm)

 

 

25” (635 mm)

 

 

 

 

 

 

 

 

 

 

Single-wall connector;

 

 

 

 

 

 

 

 

rear heat shield on

 

 

18” (460 mm)

 

 

14” (355 mm)

 

stove only

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Single-wall connector with

 

 

14” (355 mm)

 

 

14” (355 mm)

 

shields, and rear heat

 

 

 

 

 

shield on stove

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Double-wall chimney

 

 

14” (355 mm)

 

 

12” (305 mm)

 

connector

 

 

 

 

 

 

 

 

Single-wall connector

 

 

Unprotected or Protected Ceiling Surfaces

 

 

 

 

18” (460 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Clearance to Combustibles in Front of Stove

 

 

 

 

 

 

 

 

 

 

 

 

All Installations

48” (1220 mm)

 

 

 

 

 

 

 

 

 

 

 

* Using a listed double wall oval to round connector.

12

Page 12
Image 12
Vermont Casting 1910, 0968 Defiant Clearance Chart, Stove Clearance Unprotected Surfaces Protected Surfaces