Vermont Castings Defiant

Distance from the Center of the Flue Collar to the Wall

The information on this page is helpful in planning stove placement, particularly in those installations with chimneys that pass through the ceiling. However, this is not a clearance chart. Final stove clearances must adhere to the guidelines in the clearance chart on page 12.

Note that rear dimensions differ for installations with 6” or 8” chimney connectors.

Defiant With Rear Heat Shield only

Unprotected Surfaces

Parallel Installations

Corner

Installations

 

 

Side (A)

Rear (B)

Corner (C)

39¹⁄₂” (1003mm)

6” chimney:

28” (710mm)

 

27” (685mm)

 

8” chimney: 28” (710mm)

Protected Surfaces

Parallel Installations

Corner

Installations

 

 

Side (D)

Rear (E)

Corner (F)

29¹⁄₂” (710mm)

6” chimney:

25” (635mm)

 

21” (535mm)

 

8” chimney: 22” (560mm)

Defiant With Rear Heat Shield and Shielded Connector:

Side (A)

Rear (B)

Corner (C)

39¹⁄₂” (1003mm)

6” chimney:

28” (710mm)

 

17” (685mm)

 

 

8” chimney:

 

 

18” (710mm)

 

Side (D)

Rear (E)

Corner (F)

29¹⁄₂” (710mm)

6” chimney:

25” (635mm)

 

17” (535mm)

 

 

8” chimney:

 

 

18” (560mm)

 

Defiant With Rear Heat Shield and Double-wall Connector:

Side (A)

Rear (B)

Corner (C)

39¹⁄₂” (1003mm)

6” chimney:

28” (710mm)

 

17” (685mm)

 

 

8” chimney:

 

 

18” (710mm)

 

Side (D)

Rear (E)

Corner (F)

29¹⁄₂” (710mm)

6” chimney:

25” (635mm)

 

15” (535mm)

 

 

8” chimney:

 

 

16” (560mm)

 

A

*

B

C

*

D

E

F

*This distance, from the center of the flue collar to the front edge of the hearth, is the same for all installations on this page: 34” (865mm) in the United States and 36” (914mm) in Canada.

15

Page 15
Image 15
Vermont Casting 0968, 1910 Distance from the Center of the Flue Collar to the Wall, Defiant With Rear Heat Shield only