Distance from Center of Flue Collar to Wall in
Dutchwest Convection Heaters equipped with rear heat shields
NOTE: These are not clearance distances. These measurements indicate where the centerline of the flue collar will be for various installations. Measurements are from the centerline of the flue collar to the wall, not the wall protector.
A BC
D | E |
|
F |
ST427
Heater Installed with | Rear Heat Shield and: |
| Unprotected Surfaces | Protected Surfaces | ||||
| Side (A) | Rear (B) | Corner (C) | Side (A) | Rear (B) | Corner (C) | ||
33” | 18” | 25” | 23” | 10” | 15” | |||
Chimney Connector | (838 mm) | (457 mm) | (635 mm) | (584 mm) | (254 mm) | (381 mm) | ||
33” | 13” | 22” | 23” | 11” | 15” | |||
connector h.s. | (838 mm) | (330 mm) | (559 mm) | (584 mm) | (279 mm) | (381 mm) | ||
33” | 23” | 25” | 23” | 13” | 17” | |||
no heat shields | (838 mm) | (584 mm) | (635 mm) | (584 mm) | (330 mm) | (432 mm) | ||
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|