Vermont Casting 7TDVP3564, 7TDVP48, 7TDVP8 Flue System, Product Listing, 39LDVT, Specifications

Models: 7TDVP12 7TDVP24 7TDVP1218 7TDVP36 7TDVP3564 7TDVP48 7TDVP8

1 3
Download 3 pages 181 b
Page 3
Image 3
39LDVT

39LDVT

OPTIONAL ACCESSORIES (Continued):

(Trim Kits continued from second page)

Louver Kits - Additional Louver Kits ( To replace all louvers in desired color, 4 sets are required ) See Price List

Filligree Louver Kits - See Price List

Perimeter Trim Kits - See Price List

Face Trim Kits - See Price List

Vent Opening for Combustible Wall

9³⁄₈"

(240 mm)

9³⁄₈"

(240 mm)

Fireplace Hearth

Framing Detail

Opening for Non-combustible Wall

Rnd.

VO584-100

7¹⁄₂" Dia.

(190 mm)

FLUE SYSTEM

7” Coaxial Direct Vent System

SPECIFICATIONS:

7” O.D

4” I.D

MINIMUM CLEARANCE TO COMBUSTIBLE MATERIAL

a)Rear Wall Vent Applications 2” top, 1” Sides & Bottom

b)Vertical Side Wall Applications 1” to All Sides

c)Vertical thru the Roof Applications 1” to All Sides

MINIMUM COMBUSTIBLE WALL/FLOOR OPENINGS

a)9 3/8” x 10 3/8” H for Rear Wall Vent Applications

b)9 3/8” W x 9 3/8” H for Vertical Side Wall/Vertical Ap- plications

MAXIMUM INSTALLATION LENGTHS

a)Rear Wall Vent Applications 20” (508mm) Vent Length

20” (508mm) Vent Length with one 45° elbow

b)Vertical Side Wall Applications

36” (914 mm) Horizontal Vent Length with 90° elbow installed directly on top of the unit

20ʼ (6 m) Horizontal Vent Length with

7.5ʼ (2.29 m) vertical rise

*Refer to manual for alternative venting distance

VERTICAL THRU THE ROOF APPLICATIONS 8ʼ (2.4 m) Minimum Vertical Rise

40ʼ (12 m) Maximum Vertical Rise

2 sets of 45° Elbows can be used in Vertical rise with 8ʼ maximum distance between elbows Two 90° elbows maximum for 10ʼ (3 m) Horizontal can be installed in Vertical Applications

*Maximum angular variation for Vertical Sidewall/Vertical Application in system is total of 270°

*Refer to installation manual for all venting restrictions with elbow use

TERMINATION CLEARANCES MINIMUM a) Horizontal

12” (305 mm) above Grade Level 18” (458 mm) to Ventilated Soffit 12” (305 mm) to Unventilated Soffit

12” (305 mm) under veranda, porch, deck or balcony

b) Vertical

24” (610 mm) Above a Roof Surface and any other obstruction within a horizontal distance

of 18” (458 mm)

*Refer to installation manual for more termination restrictions and clearance information

PRODUCT LISTING

ANSI Z21.88 - 2005/CSA 2.332005

Vented Gas Fireplace Heaters

This gas appliance should be installed by qualified installers in accordance with local building codes and the current National Fuel Gas code ANSI Z223.1 or CSA B 149.1 Installation code for Gas Burning Appliance and Equipment.

ESIG

D

N

C

D

ERTIFIE

Rev. 09/06

Page 3
Image 3
Vermont Casting 7TDVP3564 Flue System, Product Listing, 39LDVT, Specifications, Minimum Clearance To Combustible Material