Vermont Casting A232 Installation Of Remote Switch For Rn/Rp Gas Valve, OPTIONAL FAN KIT - FK24

Models: A232

1 18
Download 18 pages 33.22 Kb
Page 6
Image 6
INSTALLATION OF REMOTE

INSTALLATION OF REMOTE

SWITCH FOR RN/RP GAS VALVE

Install on/off switch assembly on either the rear right or left side of the A232 Gas Fireplace.

1.Remove the screw at the back of the cabinet top either on the left or the right side of the fireplace.

2.Position switch assembly onto the back of the fireplace, then fasten two screws as shown in Fig. 5.

3.Attach wiring under the clips on the rear casing (Fig. 5) and install wiring through the rear opening of the fireplace before connecting to the valve as shown in Fig. 4.

VALVE

 

 

 

 

TPTH

 

 

TH

 

THERMOPILE

 

 

 

 

TP

 

 

TP

 

TH

 

 

TP TH

 

 

P

PILOT

 

 

I

 

 

TOL

 

ADJ

 

 

 

ON/OFF SWITCH OR

 

 

 

 

MILLIVOLT THERMOSTAT

 

 

 

 

 

 

 

 

Fig. 4

OPTIONAL FAN KIT - FK24

It will be easier to install the fan before connecting the gas line to the fireplace.

1.Open front access door panel by pulling forward on brass lip.

2.Guide the fan through the opening at the back of the pedestal, with the outlet pointed up and the fan mounting bracket facing the back of the fireplace. The fan mounts over two studs which hold the fan just below the firebox floor. Do not install this fan on the base. Hold the fan in place with the two nuts provided. (Fig. 7)

3.Locate the fan speed control/junction box on screw studs provided on base of the fireplace. Tighten with 3/8" nuts provided.

4.Install thermal sensor element on screw studs located to the right of the gas valve on the burner base.

5.Plug in grounded service cord to a convenient wall receptacle.

THIS FAN ASSEMBLY COMES COMPLETELY WIRED TO ELIMINATE THE NEED FOR ELECTRICIANS. THIS ELECTRICAL DEVICE, WHEN INSTALLED, MUST BE ELECTRICALLY CONNECTED AND GROUNDED IN ACCORDANCE WITH LOCAL CODES. IN THE ABSENCE

On/off switch

assembly

Clips

OPTIONAL FAN KIT - FK24 Screw (through existing hole)

Screw

Wiring for milli-volt gas valves

OF LOCAL CODES, WITH THE CURRENT CSA C22.1 CANADIAN ELECTRICAL CODE.

FOR U.S.A. INSTALLATION: FOLLOW LOCAL CODES AND THE NATIONAL ELECTRICAL CODE ANSI/NFPA NO.70-1984.

Should this fan require servicing, the power supply must be disconnected. For rewiring of any replacement components see Fig. 6.

Fig. 5

A = Speed Control

C

B = Temperature Sensor

B

C = Fan

 

 

A

BLACK

WHITE

GROUND

Fig. 6

Thermal sensor location

Valve

Stud

Fan is installed at the back of the pedestal

Manual backgroundManual backgroundManual background Fan speed control/ Junction box

TOP VIEW

Fig. 7

 

- 6 -

Page 6
Image 6
Vermont Casting A232 installation instructions Installation Of Remote Switch For Rn/Rp Gas Valve, OPTIONAL FAN KIT - FK24