Clearance to Combustibles

 

Clearance to Combustibles

 

 

Back

0” (0mm)

Sides

0” (0mm)

Floor

0” (0mm)

Top

12” (305mm)

Hearth

A hearth is not mandatory but it is recommended for aesthetic purposes. We recommend a noncombustible hearth which does not obstruct heater openings.

Electrical Specifications

Voltage

120VAC/60Hz

Total Amps

12.20 Amps

Total Watts

1460 Watts

Heater Ratings

1300 Watts

 

 

Installation of Logs

1.Turn off power to the unit.

2.Follow the directions for removing the firebox. Refer to Page 6, Steps 1 through 7.

LG240

Fig. 2 Addison logset.

Addison Electric Stove

Electrical Connection

A 15 AMP, 120 Volt, 60 Hz circuit with a properly grounded outlet is required. Preferably, the stove will be on a dedicated circuit as other appliances on the same circuit may cause the circuit breaker to trip or the fuse to blow when the heater is in operation.

The unit comes standard with a 6’ (1828 mm) long three wire cord, exiting from the rear of the stove. Plan the installation to avoid the use of an extension cord. If an extension cord must be used, it must be a minumum 14AWG, three wire with grounding type plug connector and rated not less than 1875 Watts. The extension cord shall not be more than 20 feet in length.

WARNING: Electrical outlet wiring must comply with local building codes and other applicable regulations to reduce the risk of fire, electrical shock and injury to persons.

WARNING: Do not use this stove if any part of it has been under water. Immedi- ately call a qualified service technician to inspect the stove and replace any part of the electrical system.

WARNING: This stove comes with a manual circuit breaker reset near the power cord supply. In case the stove is not operating, check the circuit breaker and reset the button at the breaker. If the stove is still not operating immediately call a qualified service technician to inspect the stove.