Vermont Casting DEF33CE Service Instructions, Louvre Removal, Glass Frame Removal

Models: DEF33CE

1 12
Download 12 pages 55.89 Kb
Page 7
Image 7
SERVICE INSTRUCTIONS

SERVICE INSTRUCTIONS

Disconnect power before attempting any maintenance or cleaning to reduce the risk of fire, electrical shock or personal injury.

LOUVRE REMOVAL

To remove top louvre pull louvre up and then lift out. See Figure 7.

2.

LOUVRE REMOVALGLASS FRAME REMOVAL LOUVRE 1.

GLASS INFORMATION GLASS

PANEL

Fig. 7

 

GLASS FRAME REMOVAL

1.Turn off electrical supply to unit.

2.Let fireplace cool if it has been operating.

3.Remove top louvre. (See Louvre Removal).

4.Open lower louvre assembly.

5.Remove two door retention screws along lower edge of door frame.

6.Swing lower portion of door out from the fireplace and gently lift up to disengage top of door from fireplace. See Fig. 8.

7.To reinstall glass door, follow the above procedure in reverse.

GLASS

FRAME

FIREPLACE

FRONT

SCREWSREPLACING LIGHT BULBSManual background

CLAMPS

Manual background WINDOW

FRAME

WINDOW

SCREWS

FRAME

 

Fig. 8

GLASS INFORMATION

1.Under no circumstances should this product be operated with missing or broken glass.

2.Do not strike or slam the glass.

3.Do not use abrasive cleaners to clean the glass.

4.This product uses tempered glass. Replacement of the glass with gasket as supplied by the manufac- turer should be done by a qualified service person.

REPLACING LIGHT BULBS

This fireplace uses four clear 240 Volt, 50 Hz, 60 Watts, E-14 socket base light bulbs (chandelier candle type). Three of the lights are located under the ember bed of the unit. The fourth light is found at the top of the firebox above the log set. For convenience, if one of the bulbs burns out, it may be a good idea to replace all of the light bulbs.

Do not exceed 60 Watts per bulb. Use of higher rated bulbs may result in a fire, causing property damage, personal injury or loss of life.

1.Turn off power to the unit.

2.Let fireplace cool if it has been operating.

3.Remove top louvre. (See Louvre Removal).

4.Remove glass door. (See Glass Frame Removal).

5.Gently remove log set.

6.Remove the two screws securing the ember bed in position. One screw is located on either side of the ember bed near the front.

7.Examine the bulbs to determine which bulbs need to be replaced.

8.While holding the socket, unscrew the defective bulb(s).

9.Install the new light bulb(s) by screwing in while holding the socket.

10.Reinstall ember bed, log set, glass door and top louvre.