manual control wlth pressure regulator

 

 

 

PILOTBUHNER

 

 

6

I

 

 

,/A

 

 

 

( r . i

A

= Filter

D = PressureRegulator

B = Manualshut-off

E = Thermostat.

Q

= FlameFailureDevice

F = PilotAdjustment

TECHNTCALSPECFICATONS(EUROSTVALVE)

Inlets(2)

3/8 NPTFemale

Outlets(2)

3/8 NPTFemale

MaximumWorkingPressure

1/2PSIG

WorkingTemperature(oF)

32oFto 175oF

ThermostatRangefF)--

55oFto IOOoF(Standard)

CalibrationTemperature(oF)

, 100oFat Hl Knobposition

Max.RegulatedCapacily

N.G.4q,000BTU/hr.(')

Min.RegulatedCapacity-

1o,oooBTU/hr.

PilotFlowRate- 2.5 Ft./hrat. 0.S"PressureDrop

Weight'1.2lb.

(')Basedon 1,000BTU/Ff:0.64s.g.gasat 1.00"W.Cpressure.drop.

HIGHELEVATIONINSTALLANON

A.G.AOesign.certifiedunitsaretestedand approvedforelaationsfrom0-2000feet.CM approvedunilsarecertifiedlorelaationsfrom G4500feet.

Wheninstallingthisunitatanelentionabove 2000feet,(inUnitedStates)it isnecessaryto decreasetheinputntingby changingthe existingburnerorificet0 a smallersizelnput. shouldbereduced4percentforeach1ffi0leel aborcseala/el.Checkwiththelocalgasutility forproperorificesizeidentification.

Wheninstallingthisunitatanelaationbetneen 2000-4500leet(inCanada)$einputntingmug bereducedby10percent.

Wheninstallingthisunitatanelantionabon 45fi)(inCanada),checkwithlocalauthorities.

Consuhyourlocalgascompanylorasigancein determiningtheproperorificeloryourlocation.

Thisunitfeaturesa thermostaticilly,modulatingeurositcontrolvalvewhichrequiresno electricityto operate(Valve.shovrnon hge SI;Onceyou haveselectedyourdesiredtemperatureusingthe control knob,thetemperaturesensingO0tOwillcontroltheamountof fuelconsumedaccordinglyFor.example if yousetthecontrolknobin the Hi position(110'Rthetemperaturesensingbutbwillreducetheamount of fuelconsumedas yourroomsambienttemperaturerises.lf you haveselecteda lowersettingand youroomsambienttemperaturerisesabovethatsettingthe valvewill "shut off" the flowof gasto the burneruntilthe roomsambienttemperaturedrops,at whichtimethe valvewill automaticallyre-light.

Dueto the sensitivityof the thermostaticbulb,we recommendthatit be placedin as coola locationas possibleOne. possiblelocationisto placethebulbonyourgaspipingasfarfromthestoveas possible.The coolgasenteringyourhomewillkeepthetemperaturesensingbulbcoolallowingmaximumheatoutput.