Majestic Fireplaces® ODSR Series "A"

Chimney Supports

The chimney system is supported by the fireplace for vertical chimney heights less than 30' (9 m) above the hearth. Chimney supports are required if the vertical height exceeds 30' (9 m) with SK8 chimneys or 20' (6 m) with 3-wall chimneys. Locate chimney supports at ceil- ing holes or other structural framing at 30' (9 m) (SK8) or 20' (6 m) (3-wall) heights. Spacing between chimney supports must not exceed 30' (9 m) (SK8) or 20' (6 m) (3-wall). Use Chimney Support Model SKCS8. (NOTE:

The SKCS8 can not be mounted directly to the fireplace.) Support provided by elbow straps fulfills the support requirement only if they are spaced as previ- ously described. (A chimney support is 2¹⁄₂" (64 mm) long when installed.)

Angled chimney runs require a support every 6' (1.8 m) in addition to the elbow straps. Chimney supports are used for this function. (Fig. 8)

Chase Installation

A chase is a vertical boxlike structure which encloses the fireplace and/or chimney. Chases are typically built on the outside of the house with fireplace opening cut into the outer wall of a room. (Page 4, Fig. 3)

If you need help in determining fireplace location or how the chimney system should be run, contact your Majes- tic Fireplaces dealer for assistance.

Chimney Sup- port Strap

SKCS8

FP284

Fig. 8 Chimney support installation

Installation

Insulating Fireplace Enclosure

for Cold Climates

If you live in a cold climate, it is not required but highly recommended that you insulate fireplace enclosure to eliminate cold air penetration as much as possible.

Insulate base of fireplace with a noncombustible insulation rated for a minimum of 300°F. Insulating is very important for outside wall installations over a concrete slab. If fireplace is installed on a platform, insulation should be placed on top of the platform before fireplace is set. (Fig. 9)

When a fireplace is installed in a chase or on an outside wall, enclosure should be treated like any outside wall in a home. Insulation should be installed on the inside wall as well as the outside wall(s). In a chase, it is also a good idea to install a firestop at the first ceiling level above the fireplace and enclose the chase with sheeting material. Insulation may then be installed above sheeting material to assure the space around the fireplace is totally protected. (Fig. 3)

When installing the chimney, DO NOT caulk be- tween outer pipe and firestop. It is vital that some air be allowed to flow through this very thin gap.

CAUTION: WHEN INSTALLING A FIREPLACE IN AN INSULATED ENCLOSURE, BE SURE ALL RE- QUIRED AIR SPACES ARE MAINTAINED. (Page 12, Fig. 19)

Hard Flat

Surface

Insulation

Platform

FP555

Fig. 9 Insulating between platform and fireplace.

8

20006811

Page 8
Image 8
Vermont Casting ODSR42A manual Chimney Supports, Chase Installation, Insulating Fireplace Enclosure For Cold Climates

ODSR42A, ODSR36A specifications

Vermont Castings has long been renowned for producing high-quality, efficient, and aesthetically pleasing heating solutions. The ODSR36A and ODSR42A gas fireplaces represent the epitome of this legacy, combining advanced technology and design to enhance any living space.

One of the standout features of both models is their exceptional heating capabilities. The ODSR36A offers a maximum input of approximately 36,000 BTUs, while the ODSR42A boasts an impressive 42,000 BTUs. This ensures that they can effectively heat spaces of various sizes, making them suitable for both small and large rooms.

The design of these fireplaces is another notable characteristic. Both models come with a classic cast iron finish that provides a timeless aesthetic to any home. The large viewing area offered by the expansive glass doors invites warmth and ambiance into the room, allowing users to enjoy the beauty of the flames without the hassle of traditional wood-burning fireplaces.

Efficiency is paramount for modern consumers, and both the ODSR36A and ODSR42A excel in this department. With a remarkable thermal efficiency rating, these models ensure that more heat is produced from less fuel, translating into cost savings over time. Additionally, the convenience of gas operation eliminates the need for wood storage, ashes, and the cleanup associated with traditional fireplaces.

Safety and user-friendliness are also integrated into the design of the ODSR series. Both models are equipped with pilot ignition systems, simplifying the lighting process. Moreover, they come with advanced safety features such as a safety shut-off mechanism, which automatically activates in case of gas leaks, ensuring peace of mind for users.

The ODSR36A and ODSR42A also offer customizable options to suit different tastes and home styles. Choices include a variety of trims and decorative elements, allowing homeowners to create a fireplace that matches their décor.

With quiet operation, quick heat-up times, and minimal emissions, the Vermont Castings ODSR36A and ODSR42A stand out as top choices for those seeking the perfect combination of style, efficiency, and technological innovation in their home heating solutions. These fireplaces not only serve as functional heating units but also as beautiful focal points that enhance the comfort and charm of any living space.