Vermont Casting UC181L, UC241L, UE181N manual Hood Installation for Masonry Fireplaces ONLY, 3311243

Models: UE241N UE181L UE181N UC241L UC181N UE241L UC181L UC241N

1 14
Download 14 pages 49.15 Kb
Page 7
Image 7
Fig. 3 Hood installation without door track.

If the fireplace has glass doors, remove the glass doors and frame assembly or the upper door track.

If the upper door track has been removed, follow the instructions for Figure 3. If the upper door track remains, skip Figure 3 and follow the instructions for Figure 4.

2.If the upper door track has been removed, hold the adjustable hood (not included) in position with the front of its vertical hood projection flush with the front face of the fireplace.

3.Drill 3/32” holes through the upper panel, using the slots in the top of the vertical hood projection as your guide.

4.Remove any existing screws which interfere with a flush fit of the hood to the surround top.

5.Attach the hood (not provided) to the surround top with #8 x 1/2” self tapping screws (supplied with hood assembly).

Drill 3/32” Dia.

Hole

Connector

Slot

#8 x 1/2” Self- tapping Screws

Left Filler Panel

Fig. 4 Hood installation with top door track.Hood Installation for #8 x 1/2” Self- tapping Screws

FP613

Fig. 3 Hood installation without door track.

6.Slide the vertical projection of the hood into the door track and drill 3/32” holes through the track and the front panel, using the slots in the top of the vertical hood projection as your guide. Attach the hood with #8 x 1/2” self-tapping screws (supplied with hood assembly).

7.Drill 3/32” holes in the surround sides of the fireplace and attach the filler panels with #8 x 1/2” self-tapping screws (supplied with hood assembly).

Drill 3/32” Dia.

Hole

Upper Door

Track

Connector

Slot

Left Filler Panel

 

Fasten to

#8 x 1/2” Self-

 

Surround

FP613a

tapping Screws

Side

 

Fig. 4 Hood installation with top door track.

Hood Installation for

Masonry Fireplaces ONLY

1.Remove the glass door assembly if one is fitted to the fireplace.

2.Measure the fireplace opening and adjust the hood to fit the opening. The right and left filler panels (not included) should extend equally from the center piece connector (not included).

3.Hold the hood in position and mark the lintel bar, using the slots in top of the vertical hood projection as a guide.

4.Drill 3/32” holes through the lintel bar and attach the hood using the #8 x 1/2” self-tapping screws sup- plied with the hood assembly.

5.Drill the side attachment holes in the brick with a masonry drill and attach the hood to the brick with suitable masonry anchors (not provided).

Connector

Slot

 

Left Filler Panel

 

#8 x 1/2” Self-

 

tapping Screws

FP613b

Fig. 5 Masonry fireplace hood installation.

3311243

7

Page 7
Image 7
Vermont Casting UC181L manual Hood Installation for Masonry Fireplaces ONLY, 3311243, Hood installation without door track