5. Leak Testing:

￿

5. Leak Testing:

IMPORTANT: Leak testing of the appliance shall be conducted as follows:

After final gas connection is made, turn on manual gas valve and test all connections in gas supply piping and appliance for gas leaks with a soapy water solution. During this test all appliance gas valves have to be closed.

In order to avoid property damage or serious personal injury , never use a Iighted match. If a leak is present, tighten joint or unscrew, apply more joint compound, tighten again and retest connection for leak.

CONVERSION TO LP/PROPANE GAS

Every oven is provided with a set of injectors for the various types of gas. Select the injectors to be replaced according to the "INJECTORS TABLE".

The nozzle diameters, expressed in hundredths of a millimetre, are marked on the body of each injector.

SETTING THE PRESSURE REGULATOR

1.Unscrew the regulator cover;

2.Unscrew the A component, reverse and screw it according to the LP/PROPANE regulation.

LP/PROPANE

REGULATION

NATURAL GAS

REGULATION

1 CONVERSION TO LP/PROPANE GAS

SETTING THE PRESSURE REGULATOR 2

A

Fig. 6.5

INJECTORS TABLE

 

NOMINAL

REDUCED

LP/PROPANE

NATURAL GAS

 

POWER

POWER

11” W.C.P.

4” W.C.P.

BURNERS

BTU/hr

BTU/hr

Ø injector

Ø injector

[1/100 mm]

[1/100 mm]

 

 

 

 

 

 

 

 

Oven burner

11000

1500

96

164

 

 

 

 

 

Broil burner

7000

78

130

 

 

 

 

 

23