MENU MODE

GROUP

NO. MENU FUNCTION

AVAILABLE VALUES

DEFAULT SETTING

SCOPE

107

SCP 5.0 FI

5.250 - 5.499 MHz (1 kHz/step)

5.250 MHz￿1

SCOPE

108

SCP 7.0 FI

7.000 - 7.299 MHz (1 kHz/step)

7.000 MHz￿1

SCOPE

109

SCP 10.1 FI

(1)0.100 - (1)0.149 MHz (1 kHz/step)

(1)0.100 MHz￿1

SCOPE

110

SCP 14.0 FI

(1)4.000 - (1)4.349 MHz (1 kHz/step)

(1)4.000 MHz￿1

SCOPE

111 SCP 18.0 FI

(1)8.000 - (1)8.199 MHz (1 kHz/step)

(1)8.068 MHz￿1

SCOPE

112

SCP 21.0 FI

(2)1.000 - (2)1.449 MHz (1 kHz/step)

(2)1.000 MHz￿1

SCOPE

113

SCP 24.8 FI

(2)4.800 - (2)4.989 MHz (1 kHz/step)

(2)4.890 MHz￿1

SCOPE

114

SCP 28.0 FI

(2)8.000 - (2)9.699 MHz (1 kHz/step)

(2)8.000 MHz￿1

SCOPE

115

SCP 50.0 FI

(5)0.000 - (5)3.999 MHz (1 kHz/step)

(5)0.000 MHz￿1

TUNING

116

tun DIALSTEP

1 or 10 Hz

10 Hz

TUNING

117

tun CW FINE

EnA/diS

diS

TUNING

118

tun MHz SEL

1/0.1 MHz

1 MHz

TUNING

119

tun AM STEP

2.5/5/9/10/12.5 kHz

5 kHz

TUNING

120

tun FM STEP

5/6.25/10/12.5/25 kHz

5 kHz

TUNING

121

tun FM DIAL

10/100 Hz

100 Hz

TUNING

122

tun MY BAND

1.8 ~ 50/GE/AU

––

TX AUDIO

123

tAUd EQ1 FRQ

OFF/100 ~ 700 Hz (100 Hz/step)

OFF

TX AUDIO

124

tAUd EQ1 LVL

–10 ~ +10

+5

TX AUDIO

125

tAUd EQ1 BW

1 ~ 10

10

TX AUDIO

126

tAUd EQ2 FRQ

OFF/700 ~ 1500 Hz (100 Hz/step)

OFF

TX AUDIO

127

tAUd EQ2 LVL

–10 ~ +10

+5

TX AUDIO

128

tAUd EQ2 BW

1 ~ 10

10

TX AUDIO

129

tUAd EQ3 FRQ

OFF/1500 ~ 3200 Hz (100 Hz/step)

OFF

TX AUDIO

130

tUAd EQ3 LVL

–10 ~ +10

+5

TX AUDIO

131

tUAd EQ3 BW

1 ~ 10

10

TX AUDIO

132

tAUd PE1 FRQ

OFF/100 ~ 700 Hz (100 Hz/step)

200 Hz

TX AUDIO

133

tAUd PE1 LVL

–10 ~ +10

–10

TX AUDIO

134

tAUd PE1 BW

1 ~ 10

2

TX AUDIO

135

tAUd PE2 FRQ

OFF/700 ~ 1500 Hz (100 Hz/step)

800 Hz

TX AUDIO

136

tAUd PE2 LVL

–10 ~ +10

–3

TX AUDIO

137

tAUd PE2 BW

1 ~ 10

1

TX AUDIO

138

tUAd PE3 FRQ

OFF/1500 ~ 3200 Hz (100 Hz/step)

2100 Hz

TX AUDIO

139

tUAd PE3 LVL

–10 ~ +10

+6

TX AUDIO

140

tUAd PE3 BW

1 ~ 10

1

TX GNRL

141

tGEn BIAS

––

––￿2

TX GNRL

142

tGEn MAX PWR

10/20/50/100 W

100 W

TX GNRL

143

tGEn PWRCTRL

ALL/Car

ALL

TX GNRL

144

tGEn ETX-GND

EnA(ENABLE)/diS(DISABLE)

diS(DISABLE)

TX GNRL

145

tGEn TUN PWR

10/20/50/100 W

100 W

TX GNRL

146

tGEn VOX SEL

nic/dAtA

nic

TX GNRL

147

tGEn EMRGNCY

EnA(ENABLE)/diS(DISABLE)

diS(DISABLE)

￿1: Requires optional DMU-2000 Data Management Unit.