MENU MODE

GENERAL GROUP

032 GEnE TRACK

Function: Sets the VFO Tracking feature.

Available Values: OFF/bAND/FrEq

Default Setting: OFF

OFF: Disables the VFO Tracking feature.

bAND: When you change bands on the Main (VFO-

A)side, the Sub (VFO-B) band’s VFO will automatically change to be the same as that of VFO-A.

FrEq: This function is the almost same as “bAND,” however, furthermore, the Sub band’s (VFO-

B)frequency changes together with the Main Band’s (VFO-A) frequency when turning the Main Dial Tuning knob.

033 GEnE TX TOT

Function: Sets the Time-Out Timer countdown time.

Available Values: OFF/5/10/15/20/25/30 min

Default Setting: OFF

The Time-Out Timer shuts off the transmitter after continuous transmission of the programmed time.

034 GEnE TRV SET

Function: Sets the 10’s and 1’s of the MHz digits display for operation with a transverter.

Available Values: 30 ~ 49 MHz

Default Setting: 44 MHz

The default setting would be used with a 144 MHz transverter. If you connect a 430 MHz transverter to the radio, set this menu to “30” (the “100 MHz” digits are hidden on this radio).

035 GEnE µT DIAL

Function: Selects the µ-TUNE mode.

Available Values: StP1/ StP2/OFF

Default Setting: StP1

StP-1: Activates the µ-TUNE system using “COARSE” steps of the [VRF] knob (2 steps/ click) on the 7 MHz and lower amateur bands. On the 10/14 MHz bands, “FINE” [VRF] knob steps (1 step/click) will be used.

StP2: Activates the µ-TUNE system using “FINE” steps of the [VRF] knob (1 step/click) on the 14 MHz and lower amateur bands on the Main band (VFO-A).

OFF: Disables the µ-TUNE system. Activates the VRF feature on the 14 MHz and lower amateur bands on the main band (VFO-A).

ADVICE:

If the optional RF µTuning Kit is not connected, this adjustment has no effect.

036 GEnE SNB LVL

Function: Adjusts the Sub band (VFO-B) receiver’s IF Noise Blanker level, when the Noise Blanker is engaged. Available Values: nAin(MAIN)/0~100

Default Setting: nAin(MAIN)

When this menu is set to “nAin(MAIN),” you may adjust the Noise Blanker level using the front panel’s [NB] knob.

037 GEnE SUB FIL

Function: Defines the Sub band (VFO-B) receiver’s CW narrow filter.

Available Values: 1200/300/500 Hz

Default Setting: 1200 Hz

ADVICE:

This Menu item tells the microprocessor which (if any) optional filter has been installed.

038 GEnE MIC SCN

Function: Enables/disables scanning access via the microphone’s [UP]/[DWN] keys.

Available Values: On/OFF

Default Setting: On

039 GEnE SCN RSM

Function: Selects the Scan Resume mode.

Available Values: CAr/5SEc

Default Setting: 5SEc

CAr: The scanner will hold until the signal disappears, then will resume after one second.

5SEc: The scanner will hold for five seconds, then resume whether or not the other station is still transmitting.

040 GEnE ANTIVOX

Function: Adjusts the Anti-VOX Trip Gain which is the level of negative feedback of receiver audio to the micro- phone, to prevent receiver audio from activating the transmitter (via the microphone) during VOX operation.

Available Values: 0 ~ 100

Default Setting: 50

041 GEnE FRQ ADJ

Function: Adjusts the reference oscillator.

Available Values: –25 ~ 0 ~ +25

Default Setting: 0

Connect a 50-Ohm dummy load and frequency counter to the antenna jack; adjust the [SUB VFO-B] knob so that the frequency counter reading is same as the VFO frequency while pressing the PTT switch.

ADVICE:

Do not perform this Menu item unless you have a high- performance frequency counter. Perform this Menu item after aging the transceiver and frequency counter sufficiently (at least 30 minutes).

FT-2000 OPERATING MANUAL