MENU MODE
GENERAL GROUP
032 GEnE TRACK
Function: Sets the VFO Tracking feature.
Available Values: OFF/bAND/FrEq
Default Setting: OFF
OFF: Disables the VFO Tracking feature.
bAND: When you change bands on the Main (VFO-
A)side, the Sub
FrEq: This function is the almost same as “bAND,” however, furthermore, the Sub band’s (VFO-
B)frequency changes together with the Main Band’s
033 GEnE TX TOT
Function: Sets the
Available Values: OFF/5/10/15/20/25/30 min
Default Setting: OFF
The
034 GEnE TRV SET
Function: Sets the 10’s and 1’s of the MHz digits display for operation with a transverter.
Available Values: 30 ~ 49 MHz
Default Setting: 44 MHz
The default setting would be used with a 144 MHz transverter. If you connect a 430 MHz transverter to the radio, set this menu to “30” (the “100 MHz” digits are hidden on this radio).
035 GEnE µT DIAL
Function: Selects the
Available Values: StP1/ StP2/OFF
Default Setting: StP1
StP2: Activates the
OFF: Disables the
ADVICE:
If the optional RF µTuning Kit is not connected, this adjustment has no effect.
036 GEnE SNB LVL
Function: Adjusts the Sub band
Default Setting: nAin(MAIN)
When this menu is set to “nAin(MAIN),” you may adjust the Noise Blanker level using the front panel’s [NB] knob.
037 GEnE SUB FIL
Function: Defines the Sub band
Available Values: 1200/300/500 Hz
Default Setting: 1200 Hz
ADVICE:
This Menu item tells the microprocessor which (if any) optional filter has been installed.
038 GEnE MIC SCN
Function: Enables/disables scanning access via the microphone’s [UP]/[DWN] keys.
Available Values: On/OFF
Default Setting: On
039 GEnE SCN RSM
Function: Selects the Scan Resume mode.
Available Values: CAr/5SEc
Default Setting: 5SEc
CAr: The scanner will hold until the signal disappears, then will resume after one second.
5SEc: The scanner will hold for five seconds, then resume whether or not the other station is still transmitting.
040 GEnE ANTIVOX
Function: Adjusts the
Available Values: 0 ~ 100
Default Setting: 50
041 GEnE FRQ ADJ
Function: Adjusts the reference oscillator.
Available Values:
Default Setting: 0
Connect a
ADVICE:
Do not perform this Menu item unless you have a high- performance frequency counter. Perform this Menu item after aging the transceiver and frequency counter sufficiently (at least 30 minutes).