5 Remote Control Pass-through mode

When PC sets the LCD monitor to Remote Control Pass through mode, the LCD shall send a three bytes packet (followed by “CR”) in response to RCU button activation. Note, that in this mode the RCU shall have no effect on the monitor function. For example: “+Volume” will not change the volume in the LCD but only sends “+Volume” code to PC over the RS232 port.

Remote Control pass-through packet format from LCD monitor to PC(ASCII)

Name

Length

RCU-Code1

RCU-Code2

CR

Byte Count

3

MSB

LSB

00D

Bytes order

1

2

3

4

Example: Remote Control pass-through when “Menu” key is pressed (1A)

Name

Length

RCU-Code1

RCU-Code2

CR

Byte Count

3

1

A

00D

Bytes order

1

2

3

4

Example: Remote Control pass-through when key “1” is pressed (01)

Name

Length

RCU-Code1

RCU-Code2

CR

Byte Count

3

0

1

00D

Bytes order