CABINET OR WALL CUTOUT

CABINET OR WALL CUTOUT

Cutout Dimensions

 

Height (A)

 

 

 

 

Minimum

16

3/4” (42.5 cm)

 

 

Maximum

17” (43.2 cm)

 

 

Width (B)

 

 

 

 

Minimum

24

3/8” (61.9 cm)

 

 

Maximum

24

11/16” (62.7 cm)

 

 

Depth (C)

 

 

 

 

Minimum

20” (50.8 cm)

 

 

 

 

 

 

ELECTRICAL OUTLET LOCATION

Outlet should NOT be in the shaded area as indicated on Illustration 1

6”

CABINET INSTALLATION

1.Place the oven adjacent to the wall or cabinet opening. Plug the power cord into the electrical outlet.

2.Carefully guide the assembled oven into the prepared opening. Slide the oven on the Exhaust Duct Assembly. See Illustration 3. Avoid pinching the cord between the oven and the wall. Adjust the position of the oven so that the feet of the oven are fitted into the recesses of the Exhaust Duct Assembly. See Illustration 4.

Illustration 4

Illustration 3

OVEN

NOTE 1: If the Depth (C) dimension is greater than 21” (53.3 cm), the outlet location may be in any area on the rear wall.

(15.2 cm)

4”

(10.2 cm)

SIDE

Cutout Dimensions Foot

Recess

NOTE 2: The floor of the opening should be constructed of plywood strong enough to support the weight of the oven and floor load (approximately 100 pounds). The floor should be level for proper operation of the oven. Be sure to check the local building code as it may require that the opening be enclosed with side, ceiling and rear partition. The proper functioning of the oven does not require the enclosure.

Illustration 1

4”

(10.2 cm)

Exhaust Duct Assembly

FRAME INSTALLATION

VMTK ONLY

EXHAUST DUCT ASSEMBLY

1.Place the Exhaust Duct in the opening. When the Exhaust Duct Assembly is in the opening correctly, the flanges will be tightly against the lower edge of the opening. See Illustration 2.

2.Secure the Exhaust Duct Assembly with the two (1/2”) screws A. IMPORTANT: Secure screws in outer hole.

 

 

Detail A

Screw A

 

 

 

Illustration 2

Flanges

Exhaust Duct Assembly

Position the FRAME ASSEMBLY to be square with the oven. Carefully place the FRAME ASSEMBLY on the oven. Check that it is level and then secure with two SCREWS B. See Illustration 5. Secure the bottom portion of the FRAME ASSEMBLY with the two remaining SCREWS B. See Illustration 5.

Illustration 5

Screw B

Screw B

Screw B

Screw B

4

5

Page 3
Image 3
Viking F20196C EN Cabinet Or Wall Cutout, Electrical Outlet Location, Cabinet Installation, Frame Installation, Oven, Side