Installation (cont.)

General Information

Installation (cont.)

3

4

Site Preparation

Note: It is recommended that a thorough site inspection be conducted PRIOR to unpacking and moving this appliance.

Site Preparation WARNING

FIRE OR ELECTRICAL

SHOCK HAZARD

DO NOT use an extension cord with this appliance. Such use may result in fire, electrical shock

or other personal injury.

• Confirm available access to adequate

 

power—see electrical requirements.

 

° Single oven units require a 30 amp circuit

 

° Double oven units require a 50 amp circuit

Note: A minimum of 2” spacing above

 

and below the oven to any adjacent items

 

is required for ventilation purposes.

It is recommended that 3/4” or thicker

 

material be utilized to create a support

BE SURE that support for this appliance is perpendicular to the front facing of the wall or cabinet before you perform the installation.

Use of a hydraulic lift is recommended for the installation of double oven units. Be careful not to bend lower trim/vent.

All openings in the wall behind the appliance or in the floor under the appliance should be sealed.

Keep appliance area clear and free from combustible materials, gasoline and other flammable vapors.

FIRE OR ELECTRICAL WARNING

DO NOT use the handle or oven door to lift the oven. Remove door before installation to ensure that it is not used to lift the unit. DO NOT lift or carry the door by the handle.

Close the door until it stops.Push in/lift door up/and then out. Repeat for all doors.

5

6

platform for this appliance.

Installation

1

2

7a

Remove racks.

White

NeutralGreen

Red

Black

Unscrew pallet screws from side of oven.

7b

Green

Neutral White

Red

Black

1

2

Remove wooden brace on front of pallet.

Open door completely. Rotate door

 

hinge to unlocked position.

Wiring option 1*

Wiring option 2*

(connect the white and green to the incoming neutral)

(connect the white to the incoming neutral,

 

attach green to grounded junction box)

*Note: Check local code to see which wiring option should be used when grounding the unit.