Maintenance

We strongly recommend regular maintenance of this ice machine. During normal operation mineral scale that is in the water supply will gradually build up on the ice making surfaces. That build up can cause excessive loading of the ice making system, which can cause premature failure. Regular removal of the mineral scale will lengthen the product’s life.

Suggested maintenance schedule: every 6 months.

Type of maintenance: Scale removal, water seal check, water reservoir check, bin drain check, air cooled condenser cleaning and storage bin sanitation.

8

Care and Cleaning

Condenser cleaning

The condenser is like the radiator on a car, it has fins and tubes that can become clogged with dirt and lint.

To clean:

1. Remove the kickplate and front service panel.

Condenser surface

2.Locate the condenser surface.

3.Vacuum the surface, removing all dust and lint.

CAUTION

DO NOT dent the fins.

4.Return the kickplate and front service panel to their original positions. Fasten them to the cabinet using the original screws.

Winterizing

1.Clean the ice making system.

2.Open the door and push and release the On/Off switch to turn the machine off.

3.Turn off the water supply.

4.Remove the back wall of the ice storage bin.

5.Remove the drain plug and drain water resevori. Return plug to its original position.

6.Drain pump models should have about 1/2 gallon of RV antifreeze (propylene glycol) poured into the ice storage bin drain.

Note: Automotive antifreeze must NOT be used.

7.Switch off and unplug the machine.

9

Page 5
Image 5
Viking F21311 EN manual Maintenance, Care and Cleaning, Condenser cleaning, To clean, Winterizing