Viking VCWH Installation Requirements, Ventilation, Utility Requirements, and trained installer

Models: VCWH

1 7
Download 7 pages 60.12 Kb
Page 5
Image 5
Installation Requirements

VENTILATION

Professional Built-In 18”H.

Wall Hood/Chimney Wall Hood

Installation Requirements

Wall Hood

Chimney Wall Hood

 

 

UTILITY REQUIREMENTS

Proper installation/ducting is

o Duct run length is for

extremely important to ensure

general reference only;

maximum performance. Use a qualified

always use a qualified and

and trained installer.

trained installer.

 

 

o Straight runs and gradual

 

DUCTING

turns are best; for example,

 

 

• Check with a qualified and

each 90° elbow is equivalent

 

trained installer or local codes

to 5’ – 10’ (1.52 –

 

for makeup air requirements,

3.05 cm) of straight run.

 

if any.

• 7” round duct for 300 – 600

 

• Max. duct run

CFM; 10” for 900 – 1500 CFM

 

o For 300 – 1,200 CFM—50’

o Never use flexible duct; it

 

(15.2 m)

creates back pressure/air

 

o For 1,500 CFM—75’

turbulence and greatly

 

(22.9 m)

reduces performance.

GAS

Not applicable

ELECTRICAL

Hardwire direct with two-wire with ground

120 VAC/60 Hz

Max. amp usage (rating includes rec. ventilator kit rating)

PLUMBING

Not applicable

Note: All CFMs are based on tests with 0.1 static pressure. Without applying static pressure (some brands do not), CFM could be greatly overstated.

Model

Ventilator Kits

InteriorExterior

Duct Size

InteriorExterior

Max. Amps

Interior Exterior

VWH2448

VIV300/600

VEV900/1200*

7” (17.8 cm)

10” (25.4 cm)

5.0/6.2

8.7/6.1

VWH3048

VIV300/600/1200*

VEV900/1200*

7”(17.8 cm)/10” (25.4 cm)

10” (25.4 cm)

5.0/6.2/8.7

8.7/6.1

VWH3648

VIV300/600/1200*

VEV900/1200*

7”(17.8 cm)/10” (25.4 cm)

10” (25.4 cm)

5.0/6.2/8.7

8.7/6.1

VWH4248

VIV600/1200*

VEV900/1200*

7”(17.8 cm)/10” (25.4 cm)

10” (25.4 cm)

6.2/8.7

8.7/6.1

VWH4848

VIV1200*

VEV1200/1500**

10” (25.4 cm)

10” (25.4 cm)

11.1

8.4/9.1

VWH5448

VIV1200*

VEV1200/1500**

10” (25.4 cm)

10” (25.4 cm)

11.1

8.4/9.1

VWH6048

VIV1200*

VEV1200/1500**

10” (25.4 cm)

10” (25.4 cm)

11.5

8.8/9.5

VWH6648

VIV1200*

VEV1200/1500**

10” (25.4 cm)

10” (25.4 cm)

11.5

8.8./9.5

VWH3678

VIV300/600/1200*

VEV900/1200*

7”(17.8 cm)/10” (25.4 cm)

10” (25.4 cm)

5.0/6.2/8.7

8.7/6.1

VWH4878

VIV1200*

VEV1200/1500**

10” (25.4 cm)

10” (25.4 cm)

11.1

8.4/9.1

VWH6078

VIV1200*

VEV1200/1500**

10” (25.4 cm)

10” (25.4 cm)

11.5

8.8/9.5

VCWH3048

DIV300/600

DEV900/1200*

7” (17.8 cm)

10” (25.4 cm)

3.9/6.0

8.7/6.0

VCWH3648

DIV300/600*

DEV900/1200*

7” (17.8 cm)

10” (25.4 cm)

3.9/6.0

8.7/6.0

VCWH4248

DIV600*

DEV900/1200*

7” (17.8 cm)

10” (25.4 cm)

6.0

8.7/6.1

VCWH4848

DIV1200*

DEV1200/1500*

10” (25.4 cm)

10” (25.4 cm)

11.5

8.5/9.2

VCWH5448

DIV1200*

DEV1200/1500

10” (25.4 cm)

10” (25.4 cm)

11.5

8.5/9.2

VCWH6048

DIV1200*

DEV1200/1500

10” (25.4 cm)

10” (25.4 cm)

11.9

8.9/9.7

VCWH6648

DIV1200*

DEV1200/1500

10” (25.4 cm)

10” (25.4 cm)

11.9

8.9/9.7

*A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill.

**It is recommended that the 1,500 CFM ventilator be used with longer duct runs.

Note: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.

P L A N N I N G A N D D E S I G N G U I D E

R E L E A S E D 1 2 / 1 / 0 7

V I K I N G R A N G E . C O M • 1 - 8 8 8 - V I K I N G 1