Viking Access Systems f1 gate manual Appendix a, Relays In General, Technical TIP Viking uses

Models: f1 gate

1 50
Download 50 pages 42.23 Kb
Page 45
Image 45

APPENDIX (A)

Relays In General

NOTE: Viking Access Systems does not provide the external safety devices and access controls. These items can be purchases from your dealer or distributor.

In General

In regards to the Viking control board, all external safety devices and access controls contain, and are, simple relays that provide an input to the Viking control board when the device is activated.

When these devices are activated, their internal relays create a contact, or short, between the “C” and “N.O.” terminals. This contact is what provides the command to the Viking control board.

!TECHNICAL TIP: Viking uses the

Normally Open “N.O.” contact from the device, excluding “fail-safe” type photo beams. In such instances, the Normally Closed “N.C.” will be used instead.

+28V

+

GND

 

 

GND

COM

N.O.

EXIT

 

 

 

 

 

Not

 

 

N.C. Used

Glossary of Terms

1.Terminal: Wire Connections.

2. Input Terminal: On the Viking control board, the terminal which is labeled for a specific command (Re- Open, Exit, Radio, etc.). The N.O. contact from the access control device is to be connected to the Input Terminal.

3.Terminal Block: On the Viking control board, a removable block containing multiple terminals.

4.Relay: The component of an access control or safety device that provides an input or command to the Viking control board.

5.“C” Relay Common Terminal: This is the relay terminal that makes contact (a short) to the N.O. terminal when the device is activated. Always wire this relay terminal to any “GND” terminal at the control board.

6.“N.O.” Relay Normally Open Terminal: The relay terminal that has an open contact to “C” while the relay is not activated, and a closed contact when the relay is activated. Almost always wire this relay terminal to an “Input Terminal” at the control board,

7.“N.C.” Relay Normally Closed Terminal: The relay terminal that has a closed contact to “C” while the relay is not activated, and an open contact when the relay is activated. This terminal is rarely used.

8.Relay Coil: Contains the terminals that provide power at the relay.

9.+” Relay Positive Terminal: The positive power pole for the relay coil. Always wire this relay terminal to any “+28v” terminal at the control board.

10. Relay Negative Terminal: The negative power pole for the relay coil. Always wire this relay terminal to any “GND” terminal at the control board.

VIKING TECHNICAL SUPPORT 1.800.908.0884

4 3

 

 

Page 45
Image 45
Viking Access Systems f1 gate manual Appendix a, Relays In General, Technical TIP Viking uses, Glossary of Terms

f1 gate specifications

Viking Access Systems has long been recognized as an industry leader in providing reliable, high-quality access control solutions, and their F1 Gate is a prominent example of this commitment to innovation and security. Designed to enhance the functionality and aesthetics of any residential or commercial property, the F1 Gate combines advanced technology with robust materials to ensure both durability and performance.

One of the standout features of the F1 Gate is its modular design. This system allows for customization according to the specific needs and preferences of the user. Whether for a driveway, garden, or secured entryway, the F1 Gate can be tailored in terms of size, style, and materials, providing versatility for any application. The gate can be crafted from high-grade steel or aluminum, ensuring long-lasting strength and resistance to weather conditions.

Incorporating cutting-edge automation technology, the F1 Gate operates smoothly and efficiently. It features a powerful motor that guarantees quick opening and closing, coupled with a silent operation to minimize disruption. Users can enjoy seamless access through a variety of control options, including remote controls, keypads, and smartphone applications, providing flexibility in managing entry points.

Safety is a top priority in the F1 Gate design. It comes equipped with advanced safety features such as obstacle detection and automatic reversing systems. These technologies ensure that the gate will halt or reverse if an obstruction is detected, protecting vehicles, pets, and pedestrians alike. Additionally, the gate can integrate with existing security systems, adding another layer of protection to properties.

The F1 Gate also boasts significant energy efficiency. With intelligent power management systems, it is designed to consume minimal energy, making it an eco-friendly choice for those conscious about their environmental impact without sacrificing functionality.

Aesthetically, Viking Access Systems understands the importance of curb appeal. The F1 Gate offers various finishes and colors, allowing users to select an option that complements their property’s architecture. The sleek design enhances the overall look while providing a secure barrier against unauthorized access.

In summary, the Viking Access Systems F1 Gate combines versatility, safety, technology, and aesthetic appeal. Its robust construction and advanced features make it an excellent choice for those seeking a reliable and stylish access solution, perfect for any environment and requirement. As technology continues to evolve, the F1 Gate stands at the forefront, embodying the future of secure access control.