Installation of the system must be done in accordance with all state and local building codes.
The condensing unit and unit cooler are connected by a liquid line and an insulated suction line that are supplied by the installer. These lines must be properly sized for the distance between the two units. After the units and the lines are installed, the system must be pressure tested. If no leaks are found, evacuate and charge system with R134A. Refrigerant amount will vary depending on the length of line set.
3. Air Sensor
The air sensor is recommended to place in the wine room. If it is in a return duct, the temperature differential may lead to erroneous readings.
4.Electrical Wiring
•We strongly recommend against the use of an extension cord. However, if you still select to use an extension cord, it is absolutely necessary that it is a UL LISTED
1) Customer Wiring
- 6 -