Vinotemp 4500SSH, 8500SSH, WM 6500SSH, WM 2500SSH manual House circuit tripping, Noisy operation

Models: WM 6500SSH WM 2500SSH 4500SSH 8500SSH

1 17
Download 17 pages 35.86 Kb
Page 14
Image 14
7. House circuit tripping

 

g.

Low voltage

g.

Check power supply

 

h.

Operating 60 Hz unit at 50Hz

h.

Use proper 60 Hz

 

i.

Sealed system problem

i.

Call service for checking loss of

 

 

 

 

refrigerant or restrictions

 

j.

Undercharge or overcharge

j.

Call service to add or remove

 

 

 

 

refrigerant

 

 

 

 

 

7. House circuit tripping

 

a.

Incorrect fuse or breaker

a.

Check for proper fuse or breaker

 

b.

Incorrect wirings

b.

Check for wirings and connections

 

c.

Failed components

c.

Call service

 

 

 

 

 

8. Noisy operation

 

a.

Mounting area not firm

a. Add support to improve installation

 

b.

Loose parts

b. Check fan blades, bearings, cabinet

 

 

 

 

washers, tubing contact and loose

 

 

 

 

screws.

 

c.

Compressor overloaded due to high

c.

Check for airflow blockage

 

 

ambient temperatures or airflow

 

 

 

 

restriction

 

 

 

d.

Malfunctioning components

d.

Call service for checking Internal

 

 

 

 

loose, inadequate lubrication and

 

 

 

 

incorrect wirings

 

 

 

 

 

- 13 -

Page 14
Image 14
Vinotemp 4500SSH, 8500SSH, WM 6500SSH, WM 2500SSH manual House circuit tripping, Noisy operation