Trouble Shooting Guide

ERROR MESSAGES

IMPORTANT: UNPLUG SPA WHENEVER ACCESSING CONTROL BOX

LS=S

Large water temperature sensor may need replacement. Reboot system.

 

If error returns open the door and remove the four screws to the metal

 

control box cover reseat the sensor in connection. If error returns, reverse sen-

 

sors and note reading if SS=S replace sensor, if LS=S stays replace board.

LS=O

Large water temperature sensor may be disconnected. Reboot system.

 

If error returns open the door and remove the four screws to the metal

 

control box cover reseat the sensor in connection. If error returns, reverse sen-

 

sors and note reading if SS=O replace sensor, if LS=O stays replace board.

SS=S

Small heater temperature sensor may need replacement. Reboot system.

 

If error returns open the door and remove the four screws to the metal

 

control box cover reseat the sensor in connection. If error returns, reverse sen-

 

sors and note reading if LS=S replace sensor, if SS=S stays replace board.

SS=O

Small heater temperature sensor may need replacement. Reboot system. If

 

error returns open the door and remove the four screws to the metal control

 

box cover reseat the sensor in connection. If error returns, reverse sensors and

 

note reading if LS=O replace sensor, if SS=O stays replace board.

HILl

Spa sensors indicate that spa water temperature is rising above 112ºF. Unplug

 

spa and allow to cool down with cover off for one hour. Power spa back up and

 

reboot. If error returns, remove filter cartridge and check for clogged filter line.

 

Turn power off to spa, open access door and remove the four screws to the

 

metal control box cover. Look for sensor connected to heater plug and switch

 

it with sensor plugged into temp plug. Power spa back up. If topside control

 

shows water temperatures and error message is no longer displayed, sensor is

 

bad and should be replaced. Power spa down, place sensors back into original

 

plug locations. After replacing defective sensor, close box and access door.

 

Power spa up and set temperature.

 

 

Pb

Miscommunication between spa side and board. Check topside connection

 

and connections to power board. Reboot system. If error returns, call technical

 

service.

ICE

Water Temperature is below 50º F. Spa is running to bring water temperature up

 

to 60º F to prevent freezing. No action needs to be performed. Spa is operating

 

properly.

FLO

Remove filter - if error goes away then it’s possibly clogged, replace it. Open the

 

door and remove the four screws to the metal control box cover, remove the

 

fuse and check for continuity. No continuity replace with new fuse. Pump is not

 

running - disconnect power to your spa , change wires on relay switch from

 

horizontal position to vertical position, turn power back on, pump must turn

 

on, if not then bad pump.