CONTROLS & OPERATING INSTRUCTIONS

Note: For best results, read each step carefully and entirely before proceeding to the next.

TESTING THE GFCI

The GFCI shuts off the electricity in a fraction of a second if there is ashort anywhere in the system. It is rec- ommended that the GFCI be tested prior to each use. Test as follows:

1.Push the TEST button on the GFCI. The RESET button with trip out, the topside digital control LED display with go out. If this does not happen,

DO NOT USE SPA. Check all wire connection to assure that all are tight and not exposed to moisture.

2.If the GFCI test properly, firmly push the REST button back into place. The topside digital control LED will come back on.

3.If the GFCI trips by itself at anytime, firmly press the reset button back into place and perform the above test. If this happens more than once,

DO NOT USE THE SPA. Check for loose wires or moisture.

The initial factory settings can be changed by following the instructions shown below.

A. Displaying Time or Water Temperature

Pressing the “PROG”button will allow switching the display between time and water temperature. The dis- played temperature is the last reading taken when the pump was operational. To verify water temperature when the pump is shut off, press the jet button and allow the pump to run for two minutes. The water tem- perature sensor will analyze the water temperature during this time period and then display the current water temperature.

B. Setting Temperature

1.Press the “PROG”button to display water temperature

2.Press the “UP”or “DOWN”arrow to select the desired temperature.

3.Press the “PROG”button to exit the programming mode.

C. Setting Time and Filtration Hours

1.Press and hold the “PROG”button for 5 seconds until the displayed hour starts to flash.

2.Press the “UP”or “DOWN”arrow to select the current hour.

3.Press the “PROG”button one or more item to display minutes.

4.Press the “UP”or “DOWN”arrow to select the current minutes

5.Press the “PROG”button one more item to display the filtration hours F=4H (default) will be flashing. Refer to “Filtration Cycles”section to determine the length of cycles (F=4H or F=8H) you prefer.

6.Press the “UP”or “DOWN”arrow to select the filtration cycle desired.

7.Press the “PROG”button to exit the programming mode.