Vita Spa U -1 3 0 Diagnostic & Troubleshooting, Resetting Your Spa, Symptom, Meaning, Action

Models: U -1 3 0

1 25
Download 25 pages 52.43 Kb
Page 21
Image 21

DIAGNOSTIC & TROUBLESHOOTING

Resetting Your Spa

Just like your computer at home, you spa electronics could get corrupted by electrical surges and operate improperly. If your spa system is not operating properly or shows any of the following messages, please reset it to see if the mal- function clears itself.

Turn power off for 15 full minutes – then – turn power back on – then- press “PROG”to show time_then_Hold “UP”for 5 seconds. Display will show 12:00p.m., indicating a successful reset (reboot).

SYMPTOM

MEANING

ACTION

Spa Inoperative

Power failure outside of spa.

Check power source

 

 

breaker / GFCI. Call

 

 

electrician if it will not

 

 

start.

MESSAGE

 

FLO

Lack of water flow through heater.

Remove filter and check for debris in the filter and filter adapter. If “FLO” remains check for closed gate valve or see priming the pumps.

HILI

Message appears if the heater

 

sensor detects 118F at heater.

Remove spa cover and let the spa water temperature cool. Reset spa.

ICE

Water in plumbing below 50F

No action required. Pump

 

 

will come on to circulate

 

 

water and then the

 

 

heater. Heater will stay on

 

 

until the water temp

 

 

reaches 60F or set temp.

LS=O or LS=S

Water temperature sensor

Reset spa, If message

 

 

returns, replace sensor

SS=O or LS=O

High Limit Sensor

Reset spa, If message

 

 

returns,replace sensor.

Pb

Break in communication

Reset spa, If message

 

 

returns,power down spa

 

 

and check control

 

 

connection to circuit

 

 

board.

— 19 —

Page 21
Image 21