VIVOTEK
User's Manual - 153
n
image_wdrc <Boolean> 0/7 Indicate whether to support WDR enhanced.
image_ iristype <string> 0/7 Indicate iris type.
image_ focusassist <Boolean> 0/7 Indicate whether to support focus assist.
7.29 Customized event script
Group: event_customtaskfile_i<0~2>
PARAMETER VALUE SECURITY
(get/set)
DESCRIPTION
name string[41] 6/7 Custom script identification of this entry.
date string[17] 6/7 Date of custom script.
time string[17] 6/7 Time of custom script.
7.30 Event setting
Group: event_i<0~2>
PARAMETER VALUE SECURITY
(get/set)
DESCRIPTION
name string[40] 6/6 Identification of this entry.
enable 0, 1 6/6 Enable or disable this event.
priority 0, 1, 2 6/6 Indicate the priority of this event:
“0” = low priority
“1” = normal priority
“2” = high priority
delay 1~999 6/6 Delay in seconds before detecting the next event.
trigger boot,
di,
motion,
seq,
recnotify,
tampering,
visignal,
vi
6/6 Indicate the trigger condition:
“boot” = System boot
“di”= Digital input
“motion” = Video motion detection
“seq” = Periodic condition
“visignal” = Video input signal loss.
“recnotify” = Recording notification.
“tampering” = Tamper detection.
“vi”= Virtual input (Manual trigger)
triggerstatus String[40] 6/6 The status for event trigger
di <integer> 6/6 Indicate the source id of di trigger.
This field is required when trigger condition is “di”.
One bit represents one digital input. The LSB
indicates DI 0.
mdwin <integer> 6/6 Indicate the source window id of motion detection.
This field is required when trigger condition is “md”.
One bit represents one window.
The LSB indicates the 1st window.
For example, to detect the 1st and 3rd windows, set
mdwin as 5.
mdwin0 <integer> 6/6 Similar to mdwin. The parameter takes effect when
profile 1 of motion detection is enabled.
vi <integer> 6/6 Indicate the source id of vi trigger.
This field is required when trigger condition is “vi”.
One bit represents one digital input. The LSB
indicates VI 0.
inter 1~999 6/6 Interval of snapshots in minutes.
This field is used when trigger condition is “seq”.
weekday 0~127 6/6 Indicate which weekday is scheduled.
One bit represents one weekday.
bit0 (LSB) = Saturday
bit1 = Friday
bit2 = Thursday
bit3 = Wednesday
bit4 = Tuesday
bit5 = Monday
bit6 = Sunday
For example, to detect events on Friday and
Sunday, set weekday as 66.
begintime hh:mm 6/6 Begin time of the weekly schedule.
endtime hh:mm 6/6 End time of the weekly schedule.
(00:00 ~ 24:00 sets schedule as always on)
lowlightcondition
<product dependent>
0, 1 6/6 Switch on white light LED in low light condition
0 => Do action at all times
1 => Do action in low-light conditions
action_do_i<0~(ndo-1
)>_enable
0, 1 6/6 Enable or disable trigger digital output.
action_do_i<0~(ndo-1
)>_duration
1~999 6/6 Duration of the digital output trigger in seconds.