VIVOTEK
180 - User's Manual
exttriggerstatus1 trigger,
normal~trigger
,
trigger~norma
l
<blank> 6/6 The status for event audio detection
profile trigger
di <integer> 1 6/6 Indicate the source id of di trigger.
This field is required when trigger
condition is “di”.
One bit represents one digital input.
The LSB indicates DI 0.
mdwin <integer> 0 6/6 Indicate the source window id of
motion detection.
This field is required when trigger
condition is “md”.
One bit represents one window.
The LSB indicates the 1st window.
For example, to detect the 1st and 3rd
windows, set mdwin as 5.
mdwin0 <integer> 0 6/6 Similar to mdwin. The parameter
takes effect when profile 1 of motion
detection is enabled.
vi <integer> 0 6/6 Indicate the source id of vi trigger.
This field is required when trigger
condition is “vi”.
One bit represents one digital input.
The LSB indicates VI 0.
valevel 0,1 0 6/6 Select audio detection event.
0: not select
1: select
Valevel0 0,1 0 6/6 Select audio detection profile event.
0: not select
1: select
inter 1~999 1 6/6 Interval of snapshots in minutes.
This field is used when trigger