Resource name

Referenced URL

 

 

system logo image

/pic/logo.gif

 

 

background image

/pic/wallppr.jpg

 

 

General format of command URL

Every configuration can be set through URL with POST method by the Administrator only.

<general format> URL[?[name=value][&name=value]……]

<method>

POST

<authorized user> root

System configuration URL

URL:

/setup/system.cgi

 

 

 

 

 

NAME

 

VALUE

DESCRIPTION

 

 

 

 

host

 

<text string shorter than 40

system name

 

 

characters>

 

 

 

 

 

method

 

keep

keep date and time unchanged

 

 

 

 

 

 

auto

use NTP server to synchronize

 

 

 

 

 

 

manu

directly adjust date and time

 

 

 

 

date

 

<yyyy/mm/dd>

year, month and date separated by

 

 

 

slash

 

 

 

 

time

 

<hh:mm:ss>

hour, minute and second separated

 

 

 

by colon

 

 

 

 

ntp

 

<domain name or IP address>

NTP server

 

 

 

 

zone

 

-12 ~ 12

time zone, 8 means GMT +8:00

 

 

 

 

- 53 -