VIVOTEK - A Leading Provider of Multimedia Communication Solutions

level

0~7

6

6/6

The levels to distinguish the importance of information.

0:LOG_EMERG

1:LOG_ALERT

2:LOG_CRIT

3:LOG_ERR

4:LOG_WARNING

5:LOG_NOTICE

6:LOG_INFO

7:LOG_DEBUG

Group: camctrl (product dependent)

 

NAME

 

 

VALUE

 

 

DEFAULT

 

 

SECURITY

 

 

DESCRIPTION

 

 

 

 

 

 

 

 

 

 

 

(get/set)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

enablehttptunnel

 

 

<boolean>

 

0

 

4/4

 

 

Enable HTTP tunnel for

 

 

 

 

 

 

 

 

 

 

 

 

 

 

camera control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Group: camctrl_c<0~(n-1)>for n channel product (capability.ptzenabled)

NAMEVALUEDEFAULT SECURITY (get/set)

panspeed

-5 ~ 5

0

1/4

 

 

 

 

tiltspeed

-5 ~ 5

0

1/4

 

 

 

 

zoomspeed

-5 ~ 5

0

1/4

 

 

 

 

autospeed

-5 ~ 5

0

1/4

 

 

 

 

focusspeed

-5 ~ 5

0

1/4

 

 

 

 

 

dwelling

0

~ 9999

0

1/4

 

 

 

 

axisx

-104 ~ 104

0

1/7

 

 

 

 

axisy

-15 ~ 28

0

1/7

 

 

 

 

preset_i<0~19>_name

string[40]

<blank>

1/4

 

 

 

 

 

preset_i<0~19>_

0

~ 255

<blank>

1/4

dwelling

 

 

 

 

 

 

 

 

 

uart

0

~ (m-1), m is

0

1/4

 

uart count

 

 

DESCRIPTION

Pan speed

Tilt speed

Zoom speed

Auto pan speed

Auto focus speed

Time to dwelling when patrol

Axis X coordinate, used internally

Axis Y coordinate, used internally

The name of preset location

The dwelling time of each preset location

select correspond uart (capability.nuart>0)

User's Manual - 83

Page 83
Image 83