Vornado SC-550-10 Electrical Connections, Light Control Outputs, Recommended Wire Size Amps Size

Models: SC-550-10

1 12
Download 12 pages 35.7 Kb
Page 5
Image 5

SC-550-10 28 Volt Installation and Operating Instructions

Page 5 of 12

ELECTRICAL CONNECTIONS

(2)#18 AWG (#16 - 2 SPKR)

2-SPKR - Connect for same phase (+ to +)

(2) #22 AWG

 

 

Auxiliary Siren Input #22 AWG (See next page)

Connect to output

 

 

 

 

 

 

 

 

 

jack, terminals or

 

 

Cutout Input #22 AWG (See next page)

speaker of radio

 

 

 

 

 

 

 

 

 

 

 

RADIO

 

 

Slide Switch Non-Progressive Output 2 #22 AWG (500mA Max.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RELAY

 

 

 

 

 

Slide Switch Non-Progressive Output 1 #22 AWG (500mA Max.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RELAY

• • • • • • • • • •

SPKR SPKR OUT2 OUT1 RAD RAD AUX CUT NEG NEG

10-PIN TERM BLOCK PLUG (CP4833-10

Screw terminals face down. Locking screws on side hold connector to amp box.

Wiring not supplied.

#14 AWG

Use second lead

for 2 - SPKR

-

BAT

+

Positive Supply

Use both terminals

#6 AWG Max. Wire Size

Each Terminal

(140A Max. Input Current)

(Not including siren amp) DIP

Switch

Radio

Volume

LIGHT CONTROL OUTPUTS

Each Light Output Protected with 25A Fuse

10A Fuse for Siren Amp

Slide Switch

Progressive Outputs (20A Max. per Output)

LOAD LOAD LOAD

Auxiliary Outputs

(20A Max. per Output)

LOAD LOAD LOAD LOAD

Recommended

Wire Size

Amps Size

5 - 10 #16

10 - 15 #14

15 - 25 #12

25 - 40 #10

40 - 60 #8

60 - 80 #6

Use next larger size if longer than 10 ft.

CP4945A

05/07/05

Page 5
Image 5
Vornado SC-550-10 operating instructions Electrical Connections, Light Control Outputs, Recommended Wire Size Amps Size