Vulcan-Hart EF3 ML-52099, EF5 ML-114944, EF4 ML-114943 Lighting The Pilot, Turning The Fryer On

Models: EF3 ML-52099 EF4 ML-114943 EF5 ML-114944

1 12
Download 12 pages 55.28 Kb
Page 8
Image 8
LIGHTING THE PILOT

LIGHTING THE PILOT

1. Turn thermostat OFF. Thermostat is located behind the door (Fig. 3).

Drain

Valve TURNING THE FRYER ON

Gas Control

Valve Knob

Thermostat

Knob

PL-40677-1

MODEL EF3

Fig. 3

2.Push gas control valve knob and turn to OFF (Fig. 4). Wait 5 minutes for unburned gas to vent.

3.Push and turn gas control valve to the "I" in PILOT (Fig. 5).

4.While still holding knob in, light the pilot with a lit taper. Continue to depress knob until pilot remains lit when knob is released.

If pilot does not remain lit, repeat Steps 2, 3, and 4.

5.Depress and turn gas control knob to ON (Fig. 6).

6.If gas supply is interrupted, repeat Steps 1-5.

Fig. 4

Fig. 5

Fig. 6

TURNING THE FRYER ON

To turn the fryer on, set the thermostat knob to the desired temperature. After the set temperature has been reached, the gas control shuts off gas flow to the burners. The pilot remains lit. The burners will cycle on and off, maintaining the set temperature.

— 8 —

Page 8
Image 8
Vulcan-Hart EF3 ML-52099, EF5 ML-114944, EF4 ML-114943 operation manual Lighting The Pilot, Turning The Fryer On