6. Remove thermopile from pilot bracket.

7. Reverse procedure to install.

PILOT ORIFICE

WARNING: SHUT OFF THE GAS BEFORE SERVICING.

WARNING: ALL GAS JOINTS DISTURBED DURING SERVICING MUST BE CHECKED FOR LEAKS. CHECK WITH SOAP AND WATER SOLUTION (BUBBLES). DO NOT USE AN OPEN FLAME.

1.Remove pilot assembly from fryer as outlined under thermopile.

2.Remove hex nut on the bottom of the pilot to expose the orifice.

3.Replace orifice and reverse procedure to assemble.

COMBINATION VALVE

WARNING: SHUT OFF THE GAS BEFORE SERVICING.

WARNING: ALL GAS JOINTS DISTURBED DURING SERVICING MUST BE CHECKED FOR LEAKS. CHECK WITH SOAP AND WATER SOLUTION (BUBBLES). DO NOT USE AN OPEN FLAME.

1. Disconnect fryer from main gas supply.

2.Remove the right hand burners as outlined under Burners (optional).

3.Disconnect lead wires from combination valve and mark for reconnecting.

4.Disconnect pilot tubing from combination valve.

5.Disconnect combination valve union (Fig.1) and pressure fitting (Fig. 2).

Fig.1

Fig. 2

6.Remove the combination valve from the fryer.

7.Reverse procedure to install.

– 7 –

Page 7
Image 7
Vulcan-Hart GHF90G, ML-135503, ML-135504, GHF91G service manual Pilot Orifice, Combination Valve

GHF90G, GHF91G, ML-135504, ML-135503 specifications

The Vulcan-Hart ML-135503, ML-135504, GHF91G, and GHF90G are renowned appliances designed to cater to the rigorous demands of commercial kitchens. These models are celebrated for their reliability, efficiency, and advanced features that enhance cooking performance.

The ML-135503 and ML-135504 models are equipped with powerful gas cooking capabilities. They feature heavy-duty cast iron grates that provide durability and excellent heat retention. The adjustable burners allow chefs to control the flame intensity with precision, ensuring that every dish is cooked to perfection. The ergonomic design of the controls enhances user experience, allowing for easy operation even in fast-paced kitchen environments. Another notable feature is the built-in drip trays that simplify cleanup, making these models not only functional but user-friendly.

On the other hand, the GHF91G and GHF90G series serve as ideal solutions for high-volume cooking requirements. These units are engineered with advanced technologies that ensure even heat distribution, allowing for consistent cooking results. The GHF series boasts a robust construction, designed to withstand the rigors of daily use in busy kitchens. Equipped with features such as adjustable thermostats and turbo broil burners, these models facilitate precise temperature control, which is critical for various cooking techniques.

In terms of energy efficiency, Vulcan-Hart has integrated features into the GHF91G and GHF90G to reduce gas consumption while maintaining high performance. This not only contributes to lower operational costs but also aligns with sustainable practices in the food service industry. Furthermore, both series prioritize safety, featuring pilot lights and flame failure devices that enhance operational security.

Overall, the Vulcan-Hart ML-135503, ML-135504, GHF91G, and GHF90G models stand out in the commercial kitchen equipment market due to their exceptional build quality, advanced technologies, and user-oriented features. Chefs and restaurateurs can rely on these appliances to deliver consistent performance, making them invaluable assets in any culinary establishment. Whether it’s grilling, frying, or simmering, these models exemplify Vulcan-Hart's commitment to innovation and excellence in kitchen solutions.