INSTALLATION REQUIREMENTS

INSTALLATION REQUIREMENTS

The model SPS600V and SPS620V water filters are designed to be installed in the cold water line only. Installation of the water filter in a hot water line can seriously damage the filter housing. The filter must be in contact with water at all times after installation. Installation must comply with any existing state or local plumbing codes.

WATER PARAMETERS

pH

6 to 9

 

 

Alkalinity

0 to 250 ppm

 

 

Chlorine

0 to 4 ppm

 

 

Hardness

0 to 300 ppm

 

 

Refer to the Water Parameters table, right, for recommended water quality limitations. If your local water supply does not meet the recommendations in the Water Parameters table, Vulcan may request that a water sample be returned for laboratory testing. After evaluation of the water test, other specific recommendations may be made for additional filtration or water treatment to make the local water supply meet the acceptable limits for use in steam generator equipment.

The recommended incoming flow rate for SPS600V is 2 gallons per minute (7.6 liters per minute). The recommended incoming flow rate for SPS620V is 4 gallons per minute (15.1 liters per minute).

The SPS600V and SPS620V water filters must be protected against freezing. Failure to do so could result in breakage of the filter housing and water leakage.

Minimum operating temperature: 45°F (7°C). Maximum operating temperature: 100°F (38°C).

Minimum operating pressure: 20 psig (138 kPa). Maximum operating pressure: 125 psig (862 kPa).

Minimum line pressure: 40 psig (276 kPa). Maximum line pressure: 125 psig (862 kPa).

If the filter pressure gauge is over 60 psig (414 kPa), you must reduce the pressure to the boiler to a maximum of 60 psig (414 kPa). Install a water pressure reducing regulator (part number 854322 or equivalent) after the filter, move the pressure gauge downstream of the regulator and set the pressure at 60 psig (414 kPa).

Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the filter.

PLUMBING CONNECTIONS

WARNING: PLUMBING CONNECTIONS MUST COMPLY WITH SAFETY AND PLUMBING CODES.

APPLICABLE SANITARY,

The filter housing on models SPS600V and SPS620V comes with 3/4" NPT internal pipe threads on the inlet side. The inlet is on the left; outlet is on the right, after the pressure gauge and the water meter. The outlet side of the water meter comes with a 3/8" NPT internal pipe thread connection.

Connect the incoming cold water line to the water filter's inlet connection (left side).

Connect the incoming water line to the boiler (or steam generator, steamer or combi oven) from the outlet side of the water filter (right side of water meter).

Steamers and combi ovens with two water connections have a boiler or steam generator feed line and a cold water drain line condenser feed line. Connect the drain line condenser feed line to the tee using the 3/8" compression fitting for 3/8" copper tubing, provided (Fig.1).

INLET

COLD WATER

DRAIN LINE

CONDENSER

CONNECTION TEE

(SUPPLIED)

OUTLET

BOILER/GENERATOR

FEED CONNECTION

Fig. 1