ELECTRICAL CONNECTION
Refer to the electrical diagram attached to the inside of the front panel and to ELECTRICAL DATA.
ELECTRICAL DATA
MODEL | Volts / Hz / Ph | Standard / Optional | Amps | Circuit Requirement |
|
|
|
|
|
| 115 / 60 / 1 | Standard | 2.0 | 15 Amp Cord/Plug |
VGL Series |
|
|
|
|
208 / 60 / 1 or 3 | Optional | 1.0 | Hard wire | |
|
|
|
|
|
| 236 / 60 / 1 or 3 | Optional | 1.0 | Hard wire |
|
|
|
|
|
Cord Connected Steam Kettles
WARNING: THE SUPPLY CORD ON THE STEAM KETTLE IS PROVIDED WITH A GROUNDING PLUG. THE OUTLET TO WHICH THIS PLUG IS CONNECTED MUST BE PROPERLY GROUNDED. IF THE RECEPTACLE IS NOT THE PROPER GROUNDING TYPE, CONTACT AN ELECTRICIAN.
Hard Wire Connected Steam Kettles
WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL CODES.
WARNING: DISCONNECT THE ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE DISCONNECT SWITCH INDICATING THAT YOUR ARE WORKING ON THE CIRCUIT.
Units equipped for 208 or 236 volt / 60 Hz, single- or
PERFORMANCE CHECK
The following items should be checked at installation by a qualified service technician.
1.Verify correct gas type.
2.Verify correct voltage, cycle and phase.
3.Gas pressure.
4.Internal gas connections.
5.Internal electrical connections.
6.Pilots — adjustment and ignition.
7.Burners — adjustment and ignition.
8.Thermostat — cycle for operation check.
9.Gas supply valve — check for operation.
10.Check hinge and lid assembly.
11.
12.Advise user on cleaning procedures.
– 6 –