Air leaks in air | • | Damaged air tank. | • | DO NOT DRILL INTO, |
tank or |
|
|
| WELD OR |
at air tank welds. |
|
|
| OTHERWISE MODIFY |
|
|
|
| AIR TANK OR IT |
|
|
|
| WILL WEAKEN. THE |
|
|
|
| TANK CAN RUPTURE |
|
|
|
| OR EXPLODE. TANK |
|
|
|
| MUST BE REPLACED. |
|
|
| • | Contact an authorized |
|
|
|
| qualified service |
|
|
|
| center. |
|
|
|
|
|
Air leaks between | • | Leaking ring. | • | Torque head screws to |
head and valve |
|
|
| 8 ft. lbs. If this does |
plate. |
|
|
| not stop leak, replace |
|
|
|
| ring. |
|
|
|
|
|
Motor will not run | • | Tank pressure exceeds | • | Let motor cool off and |
or restart. |
| pressure switch |
| overload switch will |
|
| pressure. |
| automatically reset. |
| • Wrong gauge wire or length | • | Motor will start | |
|
| of extension cord. |
| automatically when |
| • Check valve stuck open. |
| tank pressure drops | |
| • | Loose electrical connections. |
| below |
| • | Possible malfunctioning |
| of pressure switch. |
|
| motor or starting capacitor. | • | Check for proper gauge |
| • Paint spray on internal |
| wire and cord length. | |
|
| motor parts. | • | Remove and clean, or |
| • Fuse blown, circuit breaker |
| replace. | |
|
| tripped. | • | Check wiring |
| • Pressure release valve on |
| connection inside | |
|
| pressure switch has not |
| pressure switch and |
|
| unloaded head pressure. |
| terminal box area. |
|
|
| • Check fuse box for | |
|
|
|
| blown fuse and |
|
|
|
| replace, if necessary. |
|
|
|
| Reset circuit breaker. |
|
|
|
| Do not use a fuse or |
|
|
|
| circuit breaker with |
|
|
|
| higher rating than that |
|
|
|
| specified for your |
|
|
|
| particular branch |
|
|
|
| circuit. |
|
|
| • Check for low voltage | |
|
|
| • | conditions and/or |
|
|
|
| proper extension cord. |
|
|
| • | Disconnect the other |
|
|
|
| electrical appliances |
|
|
|
| from circuit or operate |
|
|
|
| the compressor on its |
|
|
|
| own branch circuit. |
|
|
|
|
|