5.4 WATLOW Series 988 User’s Manual Operation Menus, Chapter 5
Operation-System

Event Input 1 Status

Indicates whether the event input 1 circuit is open or closed (read
only).
[Ei1S] This prompt appears only if [`Ei1] (Global Menu) is set to some-
thing other than [``no].
Default
[OpEn] [CLOS]
[Ei1S] [Ei1S]

Event Input 2 Status

Indicates whether the event input 2 circuit is open or closed (read
only).
[Ei2S] This prompt appears only on controllers equipped with a second
digital event input (98_ _-_5_ _-_ _ _ _) and with [`Ei2] (Global Menu) set
to something other than [``no].
Default
[OpEn] [CLOS]
[Ei2S] [Ei2S]

Alarm 2 Low

Select the low trigger value for the output 2 alarm.
[A2LO] This prompt appears only if [`AL2] (Output Menu) is set to some-
thing other than [``no].
If Default
↓↓
lowest
[`Pr1] or [`pr2] value of value of [A2HI]
[`AL2] [`AL2] sensor [`rL1] (or [`rL2] )[A2LO]
(Output Menu) range (Input Menu)
[`dE1] or [`dE2] or [rAtE] [-999] [```0]
[`AL2] [`AL2] [`AL2] [A2LO] [A2LO]
(Output Menu)
[Ei1S][Ei2S][A2LO]