Chapter 4 – LinMB Controls and Displays.

Chapter 4 – LinMB Controls and Displays.

CONTROLS

Individual Band Controls

THRESHOLD.

0- -80dB. Default – 0.0dB

Defines the point of reference for that band’s energy. Whenever the energy in a certain band exceeds the threshold gain adjustment will be applied. For your convenience, each band has an energy meter for visual adjustment of the Threshold

GAIN.

+/- 18dB. Default 0.0dB

Sets the overall output gain of the band or the bands makeup value. This Gain control can be use to adjust the gain of the band even without any dynamics like an EQ. It is also used to adjust gain of the band that’s being compressed or expanded to make up for the headroom created buy the compressors attenuation, or make down to prevent clipping.

RANGE.

–24.0dB – 18dB. Default –6dB

Sets the possible range of the dynamic gain adjustment and also its intensity, replacing the classic “Ratio” control and adding a firm boundary to it. Negative Range means that when the energy exceeds the threshold a gain reduction will be applied, while positive Range means boosting it further. Read more about range in the next chapter.

ATTACK.

0.50 – 500ms. Defaults scaled for each band.

Defines the time it will take to apply the gain reduction from the moment the detected energy exceeds the threshold.

RELEASE.

5 – 5000ms. Defaults scaled for each band.

Waves LinMB software guide page 10 of 28

Page 10
Image 10
Waves Linear-Phase MultiBand Software Audio Processor manual LinMB Controls and Displays, Individual Band Controls