Installation (Continued)
the up direction arrow on the tee; the
notch must be to the top or flapper
valve will not work (see Figure 2).
5. Insert flapper valve into tee. Be sure
locator tab is in the notch in tee (see
Figure 2).
6. Slide clamp onto tee.
7. Insert pump into flapper valve, tilt
pump 30˚. When tilted, side with
power cord should be up (see Figure
3). Tighten clamp around the pump
and flapper valve (see Figure 2).
Pump must be
tilted as shown in
Figure 3 to prevent air locking.
8. To install float switch for standby
pump, first slide bracket into slot on
top of tee. Secure bracket with screw
provided. Remove top hex nut from
switch and slide up the cord and out
of the way. Slip cord through slot in
bracket, pull threaded stud through
hole, and secure with nut. Make sure
that float switch is above pump base
and that power wires do not interfere
with float switch or pump inlet.
9. Attach control box to the side of
battery box as shown in Figure 5. Place
battery in box, attach red cable to
positive battery post and black cable
to negative post. Put lid on box and
strap closed.
If cables are
reversed, damage to
the control box or battery could result,
and warranty will be void.
10. Place battery box within six feet of the
sump and a 115 VAC separately fused
outlet. The outlet must be protected
by a ground fault circuit interrupter
(GFCI). The area must also be clean,
dry and well-ventilated.
11. Plug the float switch, pump and
charger into the control box. The
connections are marked on the
control box.
12. Test pump operation by filling the
sump with water while the main
pump is unplugged. If the pump
operates properly, plug the charger
into the GFCI protected outlet to
begin charging the battery.
13. Protect electrical cord from sharp
objects, hot surfaces, oil and
chemicals. Avoid kinking the cord and
replace damaged components
immediately.
2
Operating Instructions And Parts Manual
Operation
Always disconnect the
power source before
attempting to install,
service, relocate or maintain the pump.
Never touch sump pump, pump motor,
water or discharge piping when pump is
connected to electrical power. Never
handle a pump or pump motor with wet
hands or when standing on wet or damp
surface or in water. Fatal electrical shock
could occur.
Risk of
electrical shock! Use a
GFCI receptacle to reduce
the risk of fatal electrical
shock.
Cutting the cord or plug will void the
warranty and make the pump
inoperable.
1. After installation, the standby pump
will start when the water level rises
above the depth that the primary
pump should start.
2. The control box has a DC charger
designed to shorten the recharging
time of your battery, and to prevent
overcharging. In addition, the control
box has a time delay which keeps the
pump from repeated, short cycles
when it shuts off. This time delay
feature will allow the pump to run
20-25 seconds after the switch
reaches the off position.
3. The control box contains a multi-
colored indicator light. When AC
power is present, the light will
indicate the charging state, and not
reflect actual battery voltage,
particularly with a defective battery.
In order for the indicator light to
provide an accurate reading, steps
“a” through “d” must be followed.
a. Unplug main AC pump and the
charger--a power off alert tone will
sound for 30 seconds.
b. Lift and release the float switch to
activate the standby pump.
c. When the pump stops, read the
test light:
Green: Indicates battery is
charged.
Yellow: Voltage is low,
indicating battery is partially
charged.
Figure 5
Control
box screw
Battery box bottom
Lead Wires
Control box
Figure 2
Flapper
valve
locator
tab
Notch
Clamp Standby sump pump
Tee
fitting
Figure 3
Incorrect Correct
Standby
sump
pump
inlet
Float
Switch
Figure 4
1“ min.
www.waynewatersystems.com