Wayne ISP40 specifications Description, Safety Guidelines, General Safety Information

Models: ISP40

1 4
Download 4 pages 45.27 Kb
Page 1
Image 1
Model ISP40
! DANGER

Operating Instructions and Parts Manual

Model ISP40

 

Limited Warranty

For two years from the date of purchase, Wayne Water Systems (“Wayne”) will repair or replace, at its option, for the original purchaser any part or parts of its Sump Pumps or Water Pumps (“Product”) found upon examination by Wayne to be defective in materials or workmanship. Please call Wayne (800-237-0987) for instructions or see your dealer. Be prepared to provide the model and serial number when exercising this warranty. All transportation charges on Products or parts

Operating Instructions and Parts ManualModel ISP40

 

 

Please completely read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.

AC/DC Sump Pump System

submitted for repair or replacement must be paid by purchaser.

This Limited Warranty does not cover Products which have been damaged as a result of accident, abuse, misuse, neglect, improper installation, improper maintenance, or failure to operate in accordance with Wayne’s written instructions.

THERE IS NO OTHER EXPRESS WARRANTY. IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO TWO YEARS FROM THE DATE OF PURCHASE. THIS IS THE EXCLUSIVE REMEDY AND ANY LIABILITY FOR ANY AND ALL INDIRECT OR CONSEQUENTIAL DAMAGES OR EXPENS- ES WHATSOEVER IS EXCLUDED.

Some states do not allow limitations on how long an implied warranty lasts, or do not allow the exclusions or limitations of

Record Serial Number here. (Serial Number is found on Pump Housing)

Description

The AC/DC Sump Pump System includes a submersible sump pump and a Power Supply/Battery Charger (PS/BC). Backup power is supplied by two 12 volt batteries (not included). The system is designed for home sump

NOTICE

This pump is not

designed to handle

 

salt water, brine, laundry discharge,

water softener, sewage, graywater or any other application which may contain caustic chemicals and/or foreign materials. Pump damage could occur if used in these applications and will void warranty.

All wiring must be

! WARNING performed by a qualified electrician.

If the basement

has water or moisture on the floor, do not walk on wet area until all power is turned off. If the shutoff box is in the basement, call an electrician. Remove pump and either repair or replace. Failure to follow this warning could result in fatal electrical shock.

incidental or consequential damages, so the above limitations might not apply to you. This limited warranty gives you specific legal rights, and you may also have other legal rights which vary from state to state.

In no event, whether as a result of breach of contract warranty, tort (including negligence) or otherwise, shall Wayne or its suppliers be liable for any special, consequential, incidental or penal damages including, but not limited to loss of profit or revenues, loss of use of the products or any associated equipment, damage to associated equipment, cost of capital, cost of substitute products, facilities, services or replacement power, downtime costs, or claims of buyer’s customers for such damages.

You MUST retain your purchase receipt along with this form. In the event you need to exercise a warranty claim, you MUST send a copy of the purchase receipt along with the material or correspondence. Please call Wayne (800-237-0987) for return authorization and instructions.

DO NOT MAIL THIS FORM TO WAYNE. Use this form only to maintain your records.

MODEL NO._______________ SERIAL NO.__________________________

INSTALLATION DATE_____________

ATTACH YOUR RECEIPT HERE

applications. When an electrical power outage occurs, the PS/BC automatically switches the sump pump to battery power so it will continue to pump water. Using LED’s (Light Emitting Diodes), the PS/BC also alerts you to potential problems.

Safety Guidelines

This manual contains information that is very important to know and understand. This information is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS. To help recognize this information, observe the following symbols.

Danger indicates

! DANGER an imminently hazardous situation which, if not avoided, will result in death or serious injury.

Warning indicates a

! WARNING potentially hazardous situation which, if not avoided, could result in death or serious injury.

Caution indicates a

! CAUTION potentially hazardous situation which, if not avoided, may result in minor or moderate injury.

NOTICE

Notice indicates

important

 

information, that if not followed, may cause damage to equipment.

General Safety

Information

Do not

! DANGER use to

pump flammable or explosive fluids such as gasoline, fuel oil, kerosene, etc. Do not use in a flammable and/or explosive atmosphere. Personal injury and/or property damage could result. Only use pump to pump clear water.

Pump

 

Battery Jumper Wire

 

 

Stainless Steel

 

AC Circuit

Filter

 

 

Breaker

 

 

Battery

 

Power

 

Supply/

Cables

 

Battery

 

 

Charger

 

 

(PS/BC)

Pump

Pump Fuse

Power

Supply/Battery

Power Cord

 

Charger (PS/BC)

 

 

 

 

Power Cord

Figure 1 – System Components

 

 

Pump Specifications

Power supply requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120V, 60 Hz Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Brushless Integral Processor Normal water removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36 GPM @ 10 Feet Liquid temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40°F to 120°F Circuit requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 amps AC (min) Pump Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .111/2” high x 93/4” base Pump starts at (factory set) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12” Water Level Pump stops at (factory set) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6” Water Level

Pump Construction

Motor housing, volute, filter cap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Cast Iron Impeller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Glass-filled Ryton®

Shaft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .410 Stainless Steel Discharge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11/2” NPT Float switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-position Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Stainless Steel

www.waynepumps.com

8

REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.

© 2007 Wayne Water Systems

For parts, product & service information

351905-001 3/07

visit www.waynewatersystems.com

Page 1
Image 1
Wayne specifications Description, Safety Guidelines, General Safety Information, DANGER use to, Model ISP40