Check for gas leaks:

1) Regulator to butane/propane cartridge connection.

mWARNING: If there is a leak at connection (1), remove butane/ propane cartridge. Do not operate grill. Use a different butane/ propane cartridge and recheck for leaks with soap-and-water solution. If a leak persists after retightening the butane/propane

cartridge, turn OFF the gas. DO NOT OPERATE THE GRILL. Contact the Customer Service Representative in your area using the contact information on our web site. Log onto www.weber.com®.

Check:

2) Valve-to-regulator connections.

mWARNING: If there is a leak at connection (2) turn OFF the gas. DO NOT OPERATE THE GRILL. Contact the Customer Service Representative in your region using the contact information on our

web site. Log onto www.weber.com®.

When leak checks are complete, turn gas supply OFF at the source and rinse connections with water.

1)

2)

GAS INSTRUCTIONS - Q 200, 220

Connecting the Butane/Propane Cylinder

Use butane/propane cylinders with a minimum capacity of 5 kg and a maximum capacity of 13 kg.

You will need: butane/propane cylinder, a soap-and-water solution and a rag or brush to apply it.

The regulator illustrations shown in this manual may not be similar to the one you are using for your barbecue, due to different country or regional regulations.

Some regulators push ON to connect and pull OFF to disconnect, others have a nut with a left-hand thread that connects to the cylinder valve. Follow specific regulator connection instructions.

Position the regulator so that the vent-hole faces downwards.

1)Mix the soap and water.

2)Turn on the cylinder valve.

3)Check for leaks by wetting the fitting with the soap-and-water solution and watching for bubbles. If bubbles form, or if a bubble grows, there is a leak.

Valve hand-wheel -

close clockwise

Regulator

Hose

Regulator vent hole.

Country

Gas type & pressure

 

 

Demark, Sweden, Norway, Finland, Iceland,

 

 

I3B/P - 30mbar

 

 

The Netherlands, Hungary, Czech Republic

 

 

 

 

 

 

 

 

 

 

United Kingdom, France, Spain, Portugal, Belgium,

 

I3+ - 28-30 / 37mbar

 

 

Ireland, Greece, Luxembourg, Italy, Switzerland

 

 

 

 

 

Germany, Austria

 

 

I3B/P - 50mbar

 

 

 

 

 

 

 

 

 

Consumption Data

 

 

 

Propane/Butane

 

Main Burner. Max

 

 

 

 

 

 

 

 

kW(Hs)

 

3.7

 

 

 

gm(Hs)

 

264

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 