Weber 3000 LX owner manual Refilling the LP tank, mDANGER, Connecting the filled LP tank

Models: 3000 LX

1 40
Download 40 pages 25.24 Kb
Page 28
Image 28
Refilling the LP tank

Refilling the LP tank

We recommend that you refill before the scale indicator reaches "E".

Note - If you run out of fuel, check the indicator setting and/or adjust the fuel scale indicator setting with the scale setting wing nut, while the tank is empty so you do not run out again.

Removal of the LP tank

1)Close tank valve (turn clockwise). Figure 5 (a).

2)Slide the collar back on the quick disconnect to disengage the fitting. Figure 5 (b).

3)Loosen tank lock wing nut and turn tank lock up out of the way.

4)Lift tank off.

To refill take LP tank and tank filler adapter to a "Gas Propane" dealer.

mWARNING: We recommend that your LP tank be filled at an authorized LP gas dealer, by a qualified attendant, who fills the tank by weight. IMPROPER FILLING IS DANGEROUS.

mWARNING: If you exchange your LP tank, make sure you get a similar tank in return. Your LP tank is equipped with a quick-disconnect valve and an OPD (Overfilling Prevention Device). Other LP tanks are not compatible with your barbecue connection.

Scale setting wing nut

Tank lock

Removal of the LP tank wing nut

(a)

Tank valve

Connecting the filled LP tankManual background Collar

(b)

Connecting the filled LP tank

mWARNING: Make sure that the LP tank valve is closed. Close by turning clockwise.

mDANGER

Do not use an open flame to check for gas leaks. Be sure there are no sparks or open flames in the area while you check for leaks. This will result in a fire or explosion which can cause serious bodily injury or death and damage to property.

You will need: LP tank, a soap and water solution and a rag or brush to apply it.

Note - Since some leak test solutions, including soap and water, may be slightly corrosive, all connections should be rinsed with water after checking for leaks

a)Lift and hook the tank onto the fuel scale.

b)Loosen the tank lock wing nut. Swing the tank lock down. Tighten the wing nut. Figure 6.

Figure 6

Figure 5

28

Page 28
Image 28
Weber 3000 LX owner manual Refilling the LP tank, mDANGER, Connecting the filled LP tank, Removal of the LP tank