5A. Power Supply: This pump requires a 115 V.,
60 Hz., 15 amp individual branch circuit. The cir- cuit must be grounded and should be dedicated to the sump pump.
5B. The pump is supplied with a
Electrical shock hazard. Always ground the pump to a suitable electrical ground, such as a grounded water pipe, a properly ground- ed metallic raceway, or a ground wire system. Do not cut off the round ground pin.
6A. After you have installed the piping, check valve, and float switch, the pump is ready for operation.
6B. Check the pump by filling the sump with water and observing the pump’s operation through one complete cycle. For switch settings see the Electrical and Switch Specifications chart on Page 5.
Failure to make this operational check may lead to improper operation, premature failure, and flooding.