Operation | 5 |
1.The shaft seal depends on water for lubrication. Do not operate the pump unless it is submerged in water; running it dry may damage the seal.
2.If the pump overheats, an
3.This pump will not remove all the water in the sump. If you are running the pump manually and water stops coming out of the discharge, the pump has probably run dry. Shut it off immedi- ately and check the water level.
TM E.I. DuPont De Nemours and Company Corporation, Delaware.
PERFORMANCE
GPH AT TOTAL FEET OF LIFT (See Figure 7)
|
|
|
|
| No flow | |
Model | 5 ft. | 10 ft. | 15 ft. | 20 ft. | at height | |
shown | ||||||
|
|
|
|
| ||
| CAPACITY GALLONS/HOUR |
| below | |||
|
|
|
|
|
| |
3983 | 4,020 | 3,540 | 3,000 | 1,800 | 26’ | |
|
|
|
|
|
| |
3984 | 4,020 | 3,540 | 3,000 | 1,800 | 26’ | |
3985 | 4,380 | 3,840 | 3,300 | 2,340 | 28’ | |
3986 | 4,380 | 3,840 | 3,300 | 2,340 | 28’ | |
3988 | 4,700 | 4,100 | 3,500 | 2,820 | 29’ |
ELECTRICAL & SWITCH SPECIFICATIONS
|
|
| Individual | *Switch Setting | |
|
| Motor | Branch | in inches | |
| Motor | Full Load | Circuit | Water Level For: | |
Model | HP | Amps | Req.(Amps) | On | Off |
3983 | 1/3 | 5.8 | 15 | 15" | 7" |
3984 | 1/3 | 5.8 | 15 | 3" | |
3985 | 1/2 | 6.3 | 15 | 15" | 7" |
3986 | 1/2 | 6.3 | 15 | 3" | |
3988 | 3/4 | 7.0 | 15 | 3" |
Discharge
Pipe
Basement |
Floor |
Lift |
Sump |
Pit |
Check Valve |
(Install Vertically) |
Figure 7 – LIFT: Lift is the vertical distance the pump actually lifts water.The higher the lift, the lower the flow.
NOTE: The friction caused by water running through the pipe will also, on longer pipe runs, reduce the flow.
For parts or assistance, call Simer Customer Service at