Weber #43028 manual Gas Instructions, Check For Gas Leaks

Models: #43028

1 20
Download 20 pages 28.04 Kb
Page 13
Image 13
GAS INSTRUCTIONS

 

GAS INSTRUCTIONS

13

 

 

CHECK FOR GAS LEAKS

(1)

 

 

 

DANGER

 

Do not use an open flame to check for gas leaks. Be

 

sure there are no sparks or open flames in the area

 

while you check for leaks. Sparks or open flames will

 

result in a fire or explosion, which can cause serious

 

bodily injury or death and damage to property.

 

 

WARNING: You should check for gas leaks every time

(2)

 

 

 

you disconnect and reconnect a gas fitting.

 

Note - All factory-made connections have been thoroughly checked for gas

 

leaks. The burner has been flame-tested. As a safety precaution however,

 

you should recheck all fittings for leaks before using your Weber® Gas Fire-

 

place. Shipping and handling may loosen or damage a gas fitting.

 

 

WARNING: Perform these leak checks even if your

 

 

fireplace was dealer or store assembled.

 

You will need: a soap and water solution, and a rag or brush to apply it.

 

Note - Since some leak test solutions, including soap and water, may be

(3)

slightly corrosive, all connections should be rinsed with water after checking

 

for leaks.

 

To perform leak checks: open cylinder valve by turning the cylinder valve

 

hand-wheel counterclockwise.

 

 

WARNING: Do not ignite burner when leak checking.

 

Check for leaks by wetting the connections with the soap and water solution

 

and watching for bubbles. If bubbles form or if a bubble grows, there is a

 

leak.

 

Check:

(4)

1) Regulator-to-Cylinder connection.

 

 

WARNING: If there is a leak at connection (1) or (2),

 

 

retighten the fitting by hand only, and recheck for

 

 

leaks with soap and water solution. If a leak persists

 

 

after retightening the fitting, turn OFF the gas. DO

 

 

NOT OPERATE THE FIREPLACE. Contact the Customer

 

 

Service Representative in your area using the contact

 

 

information on our web site. Log onto www.weber.com®.

 

Check:

 

2)

Hose-to-regulator.

 

3) Hose to bulkhead fi tting.

 

4)

Bulkhead fi tting.

 

WARNING: If there is a leak at connections (2), (3), or (4), turn OFF the gas. DO NOT OPERATE THE FIREPLACE. Contact the Customer Service Representative in your area using the contact information on our web site. Log onto www.weber. com®.

When leak checks are complete, turn gas supply OFF at the source and rinse connections with water.

Page 13