Weber #43028 manual Troubleshooting, Problem, Check, Cure

Models: #43028

1 20
Download 20 pages 28.04 Kb
Page 18
Image 18
TROUBLESHOOTING

18

TROUBLESHOOTING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PROBLEM

 

CHECK

CURE

 

 

Burner burns with a dark orange

 

Inspect Spider / Insect Screen for pos-

Clean Spider / Insect Screen. (See Section

 

flame, in conjunction with heavy soot-

sible obstructions. (Blockage of holes.)

“Annual Maintenance”)

 

ing.

 

 

 

 

 

 

 

 

 

 

Burner does not light. -or - Burner has

The excess fl ow safety device, which is

To reset the excess fl ow safety device turn all

 

a small flickering flame in the HIGH

 

part of the fi replace to cylinder connec-

burner control knobs and the cylinder valve

 

position.

 

tion, may have activated.

OFF. Disconnect the regulator from the cylin-

 

 

 

 

der. Turn burner control knobs to HIGH. Wait

 

 

 

 

at least 1 minute. Turn burner control knobs

 

 

 

 

OFF. Reconnect the regulator to the cylinder.

 

 

 

 

Turn cylinder valve on slowly. Refer to “Light-

 

 

 

 

ing Instructions”.

 

 

 

 

 

 

Burner does not light, or flame is low

Is LP fuel low or empty?

Refi ll LP cylinder.

 

in HIGH position.

 

 

 

 

 

 

Is fuel hose bent or kinked?

Straighten fuel hose.

 

 

 

 

 

 

 

 

 

 

 

 

Is igniter functioning properly?

Replace igniter (see contact info. below).

 

 

 

 

 

 

 

 

 

Is the igniter box blocked?

Remove obstructions from igniter box (see

 

 

 

 

pg. 10, Step 11 of “Assembly” Section).

 

 

 

 

 

 

 

Flame seems to lose heat when

 

Is there frost/ice on the outside of

Turn off burner control knobs and

 

burning in cold weather temperatures

the LP cylinder?

the LP cylinder. Replace with a

 

50° F or colder. (The liquid propane in

 

spare LP cylinder and resume

 

the cylinder turns to vapor too slowly

 

burning.

 

to supply the burners with gas. This is

 

WARNING: The spare or

 

due to the air temperature cooling the

 

disconnected LP cylinder must

 

LP cylinder which slows the

 

 

be stored outdoors in a well

 

vaporization process.)

 

 

ventilated area out of the reach

 

 

 

 

of children.

 

 

 

 

 

 

Burner flame pattern is erratic. Flame

Are burner holes blocked?

Clean burner holes. (See Maintenance Sec-

 

is low when burner is on HIGH. Flames

 

tion.)

 

do not ignite all burner holes.

 

 

 

 

 

 

 

 

 

 

If problems cannot be corrected by using these methods, please contact the Customer Service Representative in your area using the contact information on our web site. Log onto www.weber.com®.