8
instALL GAs sUPPLY

General specifications for Piping

Note: Contact your local municipality for building codes regulating outdoor
gas barbecue installations. In absence of Local Codes, you must conform to
the latest edition of the National Fuel Gas Code: ANSI Z 223.1/NFPA 54, or CAN/
CGA-B149.1, Natural Gas and Propane Installation Code. WE RECOMMEND THAT THIS
INSTALLATION BE DONE BY A PROFESSIONAL.
Some of the following are general requirements taken from the latest edition of the
National Fuel Gas Code: ANSI Z 223.1/NFPA 54, or CAN/CGA-B149.1, Natural Gas and
Propane Installation Code for complete specifications.
• Thisbarbecueisdesignedtooperateat4.5inchesofwatercolumnpressure(.163psi).
• Amanualshut-offvalvemustbeinstalledoutdoors,immediatelyaheadofthequick
disconnect.
• Anadditionalmanualshut-offvalveindoorsshouldbeinstalledinthebranchfuelline
in an accessible location near the supply line.
• Thequickdisconnectconnectstoa1/2inchNPTthreadfromthegassource.The
quick disconnect fitting is a hand-operated device that automatically shuts off the flow
of gas from the source when the barbecue is disconnected.
• Thequickdisconnectfittingcanbeinstalledhorizontally,orpointingdownward.
Installing the fitting with the open end pointing upward can result in collecting water
and debris.
• Thedustcovers(suppliedplasticplugs)helpkeeptheopenendsofthequick
disconnect fitting clean while disconnected.
• Pipecompoundshouldbeusedwhichisresistanttotheactionofnaturalgaswhen
connections are made.
• Theoutdoorconnectormustbefirmlyattachedtorigid,permanentconstruction.
m wArninG: do not route the 10 foot hose under a deck. the hose must be visible.

Gas Line Piping

• Ifthelengthofthelinerequireddoesnotexceed50feet,usea5/8"O.D.tube.One
size larger should be used for lengths greater than 50 feet.
• Gaspipingmaybecoppertubing,typeKorL;polyethyleneplastictube,witha
minimum wall thickness of .062 inch; or standard weight (schedule 40) steel or
wrought iron pipe.
• Coppertubingmustbetin-linedifthegascontainsmorethan0.3gramsofhydrogen
sulfide per 100 cubic feet of gas.
• Plastictubingissuitableonlyforoutdoor,undergrounduse.
• Gaspipingincontactwithearth,oranyothermaterialwhichmaycorrodethepiping,
must be protected against corrosion in an approved manner.
• Undergroundpipingmusthaveaminimumof18"cover.

test Connections

All connections and joints must be thoroughly tested for leaks in accordance with local
codes and all listed procedures in the latest edition of the National Fuel Gas Code: ANSI
Z 223.1/NFPA 54, or CAN/CGA-B149.1
m dAnGer
do not use an open flame to check for gas leaks. be sure there are no sparks or open flames in the area while you check for gas leaks. this will result in a fire or explosion which can cause serious bodily injury or death and damage
to property.
GAS INSTRUcTIoNS
this is a typical installation of a weber® natural gas barbecue.
Local codes may require different installations.
INSIDE WALL
1Gas Supply 2Shut off
oUTSIDE WALL
3Quick-Disconnect 4½"PipeNipple
5Locking Shut Off 6Do Not Use