Weber 89369 manual Sideburner Maintenance, Rotisserie Troubleshooting, Side Burner Maintenance

Models: 89369

1 92
Download 92 pages 44.93 Kb
Page 32
Image 32

32

SIDEBURNER MAINTENANCE

 

 

SIDE BURNER MAINTENANCE

WARNING: All gas controls and supply valves should be in the “OFF” position.

Make sure black wire is connected between the igniter and electrode. Make sure white wire is connected between the igniter and grounding clip. Spark should be a white/blue color, not yellow.

1) Igniter Wire

2) Ground wire

3) Burner

Side Burner Grate

Side Burner cap

Side Burner Ring & Head

Igniter Electrode

Control Knob

Igniter

ROTISSERIE TROUBLESHOOTING

PROBLEM

CHECK

CURE

 

 

 

Rotisserie burner does not light.

Did you hold the burner control knob in and

Try to relight burner by holding burner control knob in and continue holding in until

 

hold in for 20 seconds until after burner

20 seconds after burner has ignited.

 

ignited?

 

 

 

 

 

Did you wait to see the entire ceramic surface

When relighting burner by holding burner control knob in, wait to see the entire

 

become alight before counting 20 seconds?

ceramic surface become alight before counting 20 seconds?

 

 

 

 

Did you repeatedly use the snap ignition until

After waiting five minutes for gas to clear, try repeatedly using the snap igniter until

 

the burner ignited?

the burner ignites (refer to “Lighting the Rotisserie Burner”).

 

 

 

 

Does the igniter work (Do you see a spark

Try manually lighting the burner (refer to “Lighting the Rotisserie Burner”). Call

 

when you repeatedly use the snap igniter?

customer service.

 

 

 

General Symptoms:

The excess flow safety device, which is part of

To reset the excess flow safety device turn all burner control knobs and the cylinder

Burner does not light. -or- Burner has

the barbecue to cylinder connection, may have

valve to “OFF”. Disconnect the regulator from the cylinder. Turn burner control

a small flickering flame

activated.

knobs to “START/HI”. Wait at least 1 minute. Turn burner control knobs to “OFF”.

 

 

Reconnect the regulator to the cylinder. Turn cylinder valve on slowly. Refer to

 

 

“Lighting Instructions”.

 

 

 

If problems cannot be corrected by using these methods, please contact the Customer Service Representative in your area using the contact information on our web site. Log onto www.weber.com®.

WWW.WEBER.COM®