SIDE BURNER TROUBLESHOOTING

17

 

 

 

 

 

 

 

 

PROBLEM

CHECK

CURE

 

 

 

 

 

Side Burner does not light.

Is gas supply off?

Turn supply on.

 

 

The excess fl ow safety device, which is part

To reset the excess fl ow safety device turn all burner control knobs and the cylinder

 

of the barbecue to cylinder connection, may

valve off. Disconnect the regulator from the cylinder. Turn burner control knobs to

 

have activated.

START/HI. Wait at least 1 minute. Turn burner control knobs to “OFF”. Reconnect

 

 

the regulator to the cylinder. Turn cylinder valve on slowly. Refer to “Lighting Instruc-

 

 

tions”.

 

 

 

 

 

Flame is low in “HI” position.

Is the fuel hose bent or kinked?

Straighten hose.

 

 

 

 

 

Push button ignition does not work.

Does burner light with a match?

If match lights burner, check igniter (see Sideburner Maintenance).

 

 

 

 

 

If problems cannot be corrected by using these methods, please contact the Customer Service Representative in your area using the contact information on our web site. Log onto www.weber.com®.

SIDE BURNER MAINTENANCE

SIDE BURNER MAINTENANCE

WARNING: All gas controls and supply valves should be in the “OFF” position.

Make sure black wire is connected between the igniter and electrode. Make sure white wire is connected between the igniter and grounding clip. Spark should be a white/blue color, not yellow.

1)Igniter Wire

2)Ground wire

3)Burner

(3)

(1)

(2)

Side Burner Grate

Burner Grate

Side Burner cap

e Cap

Side Burner Ringr & Head

IgniteriterElectrode

ControlKnob

Igniter Button

Igniter

(1)

(2)

MAINTENANCE

WEBER® SPIDER /INSECT SCREENS

Your Weber® gas barbecue, as well as any outdoor gas appliance, is a target for spiders and other insects. They can nest in the venturi section (1) of the burner tubes. This blocks the normal gas fl ow, and can cause the gas to flow back out of the combustion air opening. This could result in a fi re in and around the combustion air openings, under the control panel, causing serious damage to your barbecue.

The burner tube combustion air opening is fi tted with a stainless steel screen (2) to prevent spiders and other insects access to the burner tubes through the combustion air openings.

We recommend that you inspect the Spider/Insect screens at least once a year. (See Section “Annual Maintenance”.) Also inspect and clean the the Spider/Insect screens if any of the following symptoms should ever occur:

1)The smell of gas in conjunction with the burner fl ames appearing yellow and lazy.

2)Barbecue does not reach temperature.

3)Barbecue heats unevenly.

4)One or more of the burners do not ignite.

DANGER

Failure to correct the above mentioned symptoms may result in a fire, which can cause serious bodily injury or death, and cause damage to property.

1

2

WWW.WEBER.COM®

Page 17
Image 17
Weber E/S-320 manual Side Burner Troubleshooting, Side Burner Maintenance, Weber Spider /INSECT Screens