Side Burner Troubleshooting

WARNING: Before attempting any troubleshooting steps, all gas controls and supply valves should be in the OFF position.

Problem

Check

Cure

Side Burner does not light.

Is gas supply off?

Turn supply on.

 

 

 

Flame is low in HIGH position.

Is the fuel hose bent or kinked?

Straighten hose.

 

 

 

Flame is very yellow in

Inspect the Spider/Insect Screens

Clean Spider/Insect Screens. (See

conjunction with the smell of gas,

for possible obstructions.

section “Annual Maintenance”)

 

(Blockage of holes.)

 

OR

 

 

Burner makes popping noise in

 

 

conjunction with the smell of gas.

 

 

 

 

 

Push button ignition does not

Does burner light with a match?

If match lights burner, checkigniter

work.

 

(see below).

 

 

 

Side Burner maintenance

WARNING: All gas controls and supply valves should be in the OFF position.

Check igniter:

Make sure wire is connected between igniter and electrode. Check that igniter lock nut is tight.

Note: If the igniter works loose, carefully tighten the igniter lock nut with an adjustable wrench or pliers. Adjust igniter electrode to burner. Gap should be 1/8 to 3/16 inch from tip of electrode to burner. Spark should be a white/blue color, not yellow.

1)Igniter

2)Igniter Wire

3)Venturi/Burner

(1)

 

 

(2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4)1/8 to 3/16 inch gap between electrode and burner

(4)

(3)

D-13

Page 30
Image 30
Weber Genesis Gold C manual Side Burner does not light, Flame is low in High position, Flame is very yellow, Work