Your Weber Gas Grill Manifold assembly consisting of gas manifold, valves and gas burners has been factory assembled, pressure- and flame- tested. As a safety precaution, we recommend you check the burner alignment:

1)Are the ends of the burners under the washers at the left rear and left front of the cooking box? The screws are only guides. Do not tighten.

2)Do the valves fit into the ends of the burners?

3)Are the wing nuts under the burner assembly hand tight? Do not tighten with pliers.

If you answered YES to 1, 2 and 3, the burners are correctly aligned. If you answered NO, the burners are misaligned. Contact the Customer Service Represen- tative in your region using the contact information sheet provided with your manual. Do not use grill.

(2)

(1)

(3)

Install Gas Supply

General Specifications for Piping

Note - Contact your local municipality for building codes regulating outdoor gas barbecue installa- tions. In absence of Local Codes, you must con- firm to the latest edition of ANSI Z223.1. WE REC-

OMMEND THAT THIS INSTALLATION BE DONE BY A PROFESSIONAL.

Some of the following are general requirements taken from ANISI Z223.1 latest edition for complete specifi- cations.

This barbecue is designed to operate at 7 inches of water column pressure (.2526 psi).

A manual shut-off valve must be installed outdoors, immediately ahead of the quick disconnect.

An additional manual shut-off valve indoors should be installed in the branch fuel line in an accessible location near the supply line

The quick disconnect connects to a 3/8 inch NPT thread from the gas source. The quick disconnect fitting is a hand-operated device that automatically shuts OFF the flow of gas from the source when the barbecue is disconnected

The quick disconnect fitting can be installed horizon- tally, or pointing downward. Installing the fitting with the open end pointing upward can result in collecting water and debris.

The dust covers (supplied plastic plugs) help keep the open ends of the quick disconnect fitting clean while disconnected.

Pipe compound should be used which is resistant to the action of natural gas when connections are made.

The outdoor connector must be firmly attached to

rigid, permanent construction.

￿WARNING: Do not route the 12 foot hose under a deck. The hose must be visible.

 

Gas supply

Inside wall

 

Outside wall

 

 

Shut off

Quick Disconnect

Locking shut off

 

B-4

Page 14